[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Moose Z1100 Dialing Problem



 the z1100 panel is not capable of newer  contact id etc formats and only
did slower 3/1  formats which may be problem trying to use it to some
recivers and also type of phone line service you have if you have cable tv
or voip service it will never work. you would be far ahead of game to
replace the panel there is no further tech support on panel and it has been
out of production over a decade.

"mmar via HomeKB.com" <u36358@uwe> wrote in message
news:76320234be03c@xxxxxx
> Thanks for the response!
>
> The alarm company tech tried all these steps and still
> got the same behavior. Tried different values at address 033, and
> the delay changed, but still got 8 quick tries with no connect.
>
> Do you know what section 039 should be programmed to? Is it
> 000? The alarm company tech tried changing this. Manual says
> do not program.
>
> Is it possible that the numbers aren't programmed in and that's
> why there are 8 quick tries but no connect?
>
> Buggs wrote:
>>Program 001 into section 033, an account code into sections 044-046, and
>>the
>>phone number of the central station receiver beginning at section 068. No,
>>it won't call your cell phone.
>>js
>
> --
> Message posted via HomeKB.com
> http://www.homekb.com/Uwe/Forums.aspx/security-alarms/200708/1
>




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home