"Crash Gordon" <webmaster@xxxxxxxxxxxxxxxxxxxxx> wrote in message
news:45005f9e$0$34070$815e3792@xxxxxxxxxxxxxxxxx
> btw, dialer delays are annoying.
Get used to it, by the beginning of next year all panels must follow the new
SIA standards which mandate dialer delays that cannot be programmed out of
the system. And the wonderful exit alarm...recent closings.....minimum 30
second entry delay......etc
I will feast on your pain :)
> "Don" <don@xxxxxx> wrote in message
> news:%GiKg.18369$ry2.8321@xxxxxxxxxxxxxxxxxxxxxxxxx
> | Maybe I am over looking something here but these new GE panels [NX8V2]
> that
> | have a built in 15 sec delay on the dialer in order to decrease false
> alarms
> | seem to be causing problems when used with a digital Uplink anynet
instead
> | of solving them. Customer comes in wrong door and sets off instant
alarm
> | and goes to keypad and disarms system withiin the 15 sec. digital
uplink
> | sends generic burg. Panel sends nothing. no alarm, no cancel, no
> nothing.
> | How is that going to decrease false alarms? Am I missing something?
> | At least with the old NX8 central would get alarm and cancel signals to
go
> | along with generic burg from uplink. Seems the powers that be who built
> in
> | this 15 sec delay should have thought about this or at least come up
with
> a
> | full data digital like the NX 591 was a full data analog.
> |
> |
>
>