[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: DSC 1550 exit/entry times



<Tankboy@xxxxxxx> wrote in message
news:1148849735.510483.289650@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> Hi guys,
>
> I need a hand with the entry and exit times... it seems as though I
> have set BOTH times to 120 seconds - oops!  I wanted to leave the entry
> delay as 30 secs, and the exit delay as 60 secs, and I tried a few
> times and ended up at 2 mins for each.
>
> I think I'm missing something, and I need to know exactly what key
> sequence is required to get to the 3 digit time variable.  Once you're
> in section 17, i.e.  * 8, 1500, 17 ...  do I press 2 or 02 for the Exit
> Delay Time variable (which will end up being 060 for 60 second delay)?
> Or, do I have to put in all the variables in order (entry delay, then
> exit delay, then bell cut-off time...)?
>

you simply go through everything in that section... here's the programming
for 30 second entry, 60 second exit, and everything else default...

* 8
1500
17
030
060
006
090
050
030
# #

done :)