Re: DSC general system tamper code



3 keypads 5500Z and 3 8 zone expansion modules 5108 . I believe the 5108
modules are set not to report tamper I will have to double check the jumper.

cel

"Stanley Barthfarkle" <sbarth@xxxxxxxxx> wrote in message
news:h5qSf.44143$2O6.996@xxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> What modules do you have connected?
>
>
>
> <cel@xxxxxxxxxx> wrote in message
news:Z9Cdnfd--YF-tofZRVn-vA@xxxxxxxxxxxxxx
> > How do I get rid of "general system tamper" code on a DSC 864? I used
the
> > DSC windows software to read the status I this code is set along with
TLM
> > and Low Battery. The status on the keypad only shows general system
tamper
> > as the only fault. I tried clearing out the latch error with the
software
> > but they still show up on the status rpt on the PC. I am not using a
phone
> > line yet and have disable TLM in the configuration. I don't have a bell
> > connected, so I added a 1K resistor across the bell contacts. These
> > changes
> > got rid of my TLM and Bell trouble codes, but not the general system
> > tamper?
> >
> > cel
> >
> >
>
>