[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: DSC-Cross Zone Police Code Alarm PROBLEM



they "should"


<oldmantrying@xxxxxxxxxxx> wrote in message
news:9ue192pa007boh66uh7a3968da4eh5pi5h@xxxxxxxxxx
| YES. You are correct the board appends a "1" on the front of the 4A,
| but the central station said they did not get anything for cross zone.
| But..I shall test again and ask them again to look carefully for a 14A
| or a 4A or a 140..but shouldn't they see and English string for the
| code too?
|
| THANKS
|
| On Wed, 14 Jun 2006 17:27:30 -0700, "alarman" <alarman2000@xxxxxxxxx>
| wrote:
|
| >If you programmed a 4A into the cross zone police code reporting slot,
and
| >your panel is set to transmit contact ID, the central station will
receive a
| >"14A" or possibly a "140"
| >js
| >
| ><OldManTrying@xxxxxxxxxxx> wrote in message
| >news:iro092tj73ed1vjopphfur0r91fa6ab1tg@xxxxxxxxxx
| >> This old man needs help from an expert-I'm stumped.
| >> I have a 1 1/2 year old self installed/programmed-DSC 832 System. The
| >> Board is labeled 50/300. Thus far everything seems to work fine
| >> except:
| >>
| >> In my residence I wish to use the Cross Zone Police Code feature to
| >> reduce FALSE ALARMS from a single zone. I have programmed
| >> [328]Miscellaneous Alarm Reporting Codes, Option #6 Cross Zone Police
| >> Code Alarm as "4A".
| >>
| >> Today I did 3 tests.The  central station got alarms for both the entry
| >> zones &  the MIR zones correctly but did not receive the 4A code.
| >>
| >> Typically I would want them to dispatch police after intruder violates
| >> a perimeter/entry zone and an interior MIR (or less likely 2
| >> perimeter/entry type zones) The Cross Zone Police Code Alarm  seems
| >> perfect for doing that. They would dispatch if "4A" is received & they
| >> could not contact us by phone.
| >>
| >> FYI, I use my LCD keypad for programming and have tripled checked that
| >> [328] option #6 is "4a". HELP PLEASE. THANKS
| >
|




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home