Re: DSC-Cross Zone Police Code Alarm PROBLEM



If you programmed a 4A into the cross zone police code reporting slot, and
your panel is set to transmit contact ID, the central station will receive a
"14A" or possibly a "140"
js

<OldManTrying@xxxxxxxxxxx> wrote in message
news:iro092tj73ed1vjopphfur0r91fa6ab1tg@xxxxxxxxxx
> This old man needs help from an expert-I'm stumped.
> I have a 1 1/2 year old self installed/programmed-DSC 832 System. The
> Board is labeled 50/300. Thus far everything seems to work fine
> except:
>
> In my residence I wish to use the Cross Zone Police Code feature to
> reduce FALSE ALARMS from a single zone. I have programmed
> [328]Miscellaneous Alarm Reporting Codes, Option #6 Cross Zone Police
> Code Alarm as "4A".
>
> Today I did 3 tests.The  central station got alarms for both the entry
> zones &  the MIR zones correctly but did not receive the 4A code.
>
> Typically I would want them to dispatch police after intruder violates
> a perimeter/entry zone and an interior MIR (or less likely 2
> perimeter/entry type zones) The Cross Zone Police Code Alarm  seems
> perfect for doing that. They would dispatch if "4A" is received & they
> could not contact us by phone.
>
> FYI, I use my LCD keypad for programming and have tripled checked that
> [328] option #6 is "4a". HELP PLEASE. THANKS