[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Partition set up with DSC panels



You could use either panel depending on the layout of the entry area.
If, in the entry area, there are seperate doors leading to each of the
suites, leave the outer door uncontacted and contact each of the inner
doors leading to their respective suites providing keypads at each
door.

If there is not doors leading to each of the suites, then I would
recommend an 864 with 3 partitions which the outer door is par-3.  I
have tried the common zone setup with an NX8 (for pool alarm sounder
because the builder didn't want a real one) with little sucess.

Just remember to program both master codes into par-3 so your
customer's don't have to remember more than one number..... everyone
wants the world on a plate for a penny these days....

Hope this helps.


gepeacock@xxxxxxxxx wrote:
> Newby question on best way to set up 2 partitions, here is the
> situation:
>
> House with a basement suite.  House will be on partition 1, suite will
> be on partition 2.  The suite and house share a common entry area in
> the basement.  Im considering the DSC 832 or 864 panel but havent
> bought anything yet.
>
> As I understand it, if I put the common area zone on both partitions it
> will only trip if both partitions are armed (am I right here).  Is
> there a way to set it up that if the common area is tripped and either
> partion is armed either partition code can be entered to disarm?
>
> Everything is still in the planning stages so Im not adverse to adding
> extra keypads or sensors if needed to make this situation work the best
> way possible.
>
> Thanks for the help
> Gary



alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home