[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: Programming Power632 for ContactID reporting
You posted the best reason to switch on auto CID, then it becomes just like
SIA and the signal is correct regardless of what you put in a location
"petem" <petem001@xxxxxxxxx> wrote in message
news:AESDf.42002$rX.485847@xxxxxxxxxxxxxxxxxxxxxx
> oups!!!
>
> lets check in the manual........
>
>
>
> Contact ID
>
> Contact ID is a specialized format that will communicate information
>
> using tones rather than pulses. This format allows more
>
> information to be sent faster than other formats. For example,
>
> in addition to reporting an alarm in zone one, the Contact ID
>
> format will also report the type of alarm, such as an Entry/Exit
>
> alarm.
>
> If the Contact ID uses Programmed Reporting Codes
>
> option is enabled, a two digit number from Appendix A must
>
> be entered in programming sections [320] to [353] for each
>
> event to be transmitted. The two digit number determines the
>
> type of alarm. The panel will automatically generate all other
>
> information, including the zone number.
>
> If the Contact ID uses Automatic Reporting Codes option is
>
> enabled, the panel will operate as follows:
>
> 1. If an event's reporting code is programmed as [00], the
>
> panel will not attempt to call the central station.
>
> 2. If the reporting code for an event is programmed as anything
>
> from [01] to [FF], the panel will automatically generate
>
> the zone or access code number. See Appendix A for a
>
> list of the codes which will be transmitted.
>
> NOTE:If the Automatic Contact ID option is selected, the panel
>
> will automatically generate all zone and access code numbers,
>
> eliminating the need to program these items.
>
> If the Contact ID uses Programmed Reporting Codes
>
> option is enabled, the panel will operate as follows:
>
> 1. If an event's reporting code is programmed as [00] or [FF],
>
> the panel will not attempt to call central station.
>
> 2. If the reporting code for an event is programmed as anything
>
> from [01] to [FE], the panel will send the programmed
>
> reporting code.
>
> Additional Notes on Contact ID
>
> 1. Account numbers must be four digits.
>
> 2. All reporting codes must be two digits.
>
> 3. Substitute the HEX digit 'A' for the '0'.
>
> 4. To prevent the panel from reporting an event, the reporting
>
> code should be programmed as [00].
>
> Please refer to Appendix A: "Reporting Codes"for a list of
>
> Contact ID Identifiers.
>
> Contact ID Uses Programmed/Automatic Codes . . [381]: [7]
>
>
>
> Sorry for the wrong info... ;-)
>
>
>
> and sorry Mark..
>
>
>
>
>
> "alarman" <alarman2000@xxxxxxxxx> a écrit dans le message de news:
> SxLDf.24336$jR.2839@xxxxxxxxxxxxx
> > "petem" <petem001@xxxxxxxxx> wrote in message
> > news:1vIDf.41764$rX.374879@xxxxxxxxxxxxxxxxxxxxxx
> >> there is no auto cid in power 832,in power 864 yes..
> >
> > It's a 1555 (Power 632) Not 832.
> > js
> >
> >
>
>
alt.security.alarms Main Index |
alt.security.alarms Thread Index |
alt.security.alarms Home |
Archives Home