[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: Wiring
The most likely way to wire it would be to connect one conductor from each
wire together and then the connect one conductor from each wire to the
sensor.
The above assumes that the sensors are closed loop sensors and that one wire
comes from the preceeding door/window or control panel and the other wire
goes to the next window or door.
You should test every opening on that zone after replacing the contact.
Doug L
--
<palladin@xxxxxxxxxxx> wrote in message
news:1139682343.659145.64100@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
>I had a window sensor go out in my home security system. When I pulled
> up the magnet from the window sill, the sensor wires pulled out of the
> wiring. I went through the wall to get to the wiring, and boy am I
> confused. I have two, two wire cables coming into the bottom of the
> window. The magnetic sensor has two wires. Can anyone help me with
> the correct way to reconnect the sensor? The house is wired in zones;
> I don't think each individual sensor is wired to the box, in other
> words I think each zone is wired in series. I would appreciate any
> help you can give me. Thanks.
>
alt.security.alarms Main Index |
alt.security.alarms Thread Index |
alt.security.alarms Home |
Archives Home