Re: Gemini P3200 - * ZONES FAULTED ***
Have you been into the programming mode? You may have pushed the wrong
button in programming.
<mpsully@xxxxxxxxxxx> wrote in message
news:1167586096.233162.156190@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Thanks Robert. No recent lighting or storms. I tried to download
the software from your site, but had some problems. I sent you a
separate email. If it does turn out to be a bad board, is there a
way to buy just a replacement board rather than a whole new P3200?
Any other ideas on why the system thinks all of these zones are open?
Thanks!
Robert L Bass wrote:
> > Did mother nature pay a visit recently? You know, nearby lightning
> > strike? Utility pole transformer blow up? Or something like
> > that?
>
> I've seen an occasional Napco Gemini panel lose its programming or
> otherwise behave erratically. None of the instances (and they've
> been very few) I came across involved lightning though. I'm not saying it
> couldn't happen, but when I've seen it there was no
> report from the customer of recent storm.
>
> --
>
> Regards,
> Robert L Bass
>
> =============================>
> Bass Home Electronics
> 941-866-1100
> 4883 Fallcrest Circle
> Sarasota · Florida · 34233
> http://www.bassburglaralarms.com
> =============================>