[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: Problem With ADT System - Need Advice
Yep same thing.
I'm not in CO, I can stand the cold...in my twilight years I guess. Im in
AZ...it was beootiful today, right now it's down about 40 but I'm still
wearing short pants everyday :-)
"tourman" <rh.campbell@xxxxxxxxxxxxx> wrote in message
news:1166991035.037068.164250@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
| That's what I thought you meant actually. Didn't figure you for the
| amateur parallel trick. I takeover lots of DSC but only actually
| install Paradox. They have a neat feature called "intellizoning"....two
| trips needed on one zone during a specified period programmable up to
| 48 secs max. Works to solve lots of annoying little environmental trips
| for no apparent reason, yet set correctly, it doesn't materially
| compromise the device in question.
|
| BTW, hear you got hit hard down Colorado way with snow blizzards. We
| here in Ontario, are up to 45 degrees, sunny with clear skies and clear
| roads. This has gotta be a first time ever I've seen this...hell, I
| could ride my motorcycle today if I hadn't put it away....
|
| Sheesh....crazy weather...
|
| RHC
|
| Crash Gordon wrote:
| > No not in parallel...took risky imo.
| >
| > I put them in slightly overlapping areas where a burglar would have to
cross
| > through both within a certain amount of time, then use the software
| > cross-zone feature of the panels I install to set a crosszone time 5sec
| > 10sec whatever seems right. If one zone trips it sends kinda fault, if
both
| > trip within the cross zone time it sends a real alarm. I can even
crosszone
| > a device with itself.
|
alt.security.alarms Main Index |
alt.security.alarms Thread Index |