Re: Problem With ADT System - Need Advice



No not in parallel...took risky imo.

I put them in slightly overlapping areas where a burglar would have to cross
through both within a certain amount of time, then use the software
cross-zone feature of the panels I install to set a crosszone time 5sec
10sec whatever seems right. If one zone trips it sends kinda fault, if both
trip within the cross zone time it sends a real alarm. I can even crosszone
a device with itself.



"tourman" <rh.campbell@xxxxxxxxxxxxx> wrote in message
news:1166981979.637726.156880@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
| By "cross zoning", do you mean that particular feature as set out in
| DSC panels. Or do you mean, putting in two motions looking at the exact
| same area from two different directions, but wired in parallel (so they
| both have to trip simultaneously in order to trigger the zone)
|
| I've seen the latter option done on occasion, but in one instance I
| heard of, the installer didn't aim them carefully enough at the same
| area and someone got by the motion in a real break in. I've always been
| pretty leary of using that option ever since I saw that early on in my
| installation career.....
|
| RHC
|
| Crash Gordon wrote:
| > I've also used cross-zoning two motions together to solve exteme cases.
|