[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: First Alert Fa 148c programming
142c or 145c is a 10se, pretty sure the 148c is a straight 15.
"Paul Brewington" <pbrewington@xxxxxxxxxxxxxx> wrote in message
news:5on8f2lkgvreh565kncfi4i5iq2jpa9o7s@xxxxxxxxxx
|I believe It was a FA 148 C. I will double check later today.
|
| I set the 6139 to adress 16 and 31. Neither one worked.
| The existing kp was disconnected for the testing.
| The Ademco Tech told me it was a vista 10 se.
|
|
|
|
|
| On Tue, 29 Aug 2006 06:14:09 -0700, "Crash Gordon"
| <webmaster@xxxxxxxxxxxxxxxxxxxxx> wrote:
|
| >I've never seen that msg displayed anywhere. The 148 is the same as a
Vista
| >15...the 6139 will program it. Did you have the keypad addressed
correctly
| >and programmed in the panel at *190, 191 etc?
| >
| >
| >"Paul Brewington" <pbrewington@xxxxxxxxxxxxxx> wrote in message
| >news:op38f216qg7fvoeo5qkk6cahksfdk34p98@xxxxxxxxxx
| >|I tried a 6139 keypad. It said "incompatiable keypad"
| >|
| >|
| >|
| >|
| >|
| >|
| >|
| >| On Mon, 28 Aug 2006 19:54:39 -0700, "Crash Gordon"
| >| <webmaster@xxxxxxxxxxxxxxxxxxxxx> wrote:
| >|
| >| >You can use an old 6139, or the new(er) 6160. There's no real need for
| >| >Compass...and I believe you'd need not only Compass but the FA patch
| >| >too...which may be hard to finagle if you're not in the biz.
| >| >
| >| >
| >| >
| >| >"Paul Brewington" <pbrewington@xxxxxxxxxxxxxx> wrote in message
| >| >news:9e67f2l4o1esbika40ljko5cceaf9nkv4s@xxxxxxxxxx
| >| >|I have a customer who moved into a house with this panel.
| >| >| I assume I have to buy a programming keypad or compass software for
| >| >| First Alert. Anybody have one of these for sale?
| >| >
| >
alt.security.alarms Main Index |
alt.security.alarms Thread Index |
alt.security.alarms Home |
Archives Home