Re: Multiple magnets, one zone, EOL resistor. Never works!
Maybe your alarm contact is installed backwards..... :)
BobbyD
Total nerd wrote:
>This never seems to work properly for me. Here's what I do... am I
>doing something wrong?
>I want to secure, say, 4 windows with magnets. I take two wires from
>the panel -- a green and yellow. The green wire goes uncut allllll the
>way to the last magnet and I place an EOL resistor there and join it
>with one lead on the last magnet. The yellow wire gets cut at each
>window and a magnet is placed at each cut by simply splicing in the two
>leads of the magnet. This is what I would call a series circuit. Now,
>if I open any window, the circuit is open. If all windows are closed,
>all magnets are closed and the circuit is closed with an EOL resistor
>reading 2.2K ohms. I've checked this with a meter. All I have to do
>is plug the green and yellow into a zone and program the panel that
>it's a NC zone with an EOL resistor on it. Why does it always think
>it's open? If I take the EOL resistor out and program the zone to have
>NO EOL resistor then of course it works. What the heck am I doing
>wrong??
>
>
>