That depends on what you were using for the 5 x 20 fuse. For example, A
Cooper Bussman GDA series is fast blo, fast breaking; the GDB series is fast
acting, low breaking; the GDC is time delay, low breaking. If you're using
Littlefuse brand, you have the 216, 217 and 218, each with their own
characteristic. If you replace it with a fuse that has a longer delay, you
may burn out components. It you replace it with a shorter delay fuse, you
may blow fuses when there is no fault in the circuit. A good site is
www.littlefuse.com These are available from www.digikey.com and other
vendors.