[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: DMP Hoovers
You really only have to short the J16 for a second, generally you'll hear a
faint click...then run to the keypad and do the prog.
What kind of problem are you having with the panel anyway?
"Crash Gordon" <webmaster@xxxxxxxxxxxxxxxxxxxxx> wrote in message
news:bZo%e.60$3S1.14988@xxxxxxxxxxxxxxxxxx
| On the older DMP's you have to be at the addr 1 keypad.
|
| Which panel are you working on?
|
| You don't have a whole lot of time to get to the keypad after shorting the
| J16.
|
| I've never seen System Busy come up except when you're trying to make it
| dial out manually to connect to SCS101 for remote programming session.
This
| would happen if you are hitting 948 cmd. OR if it's trying to transmit
| something to cs.
|
| You really should get training...it's free you know. They'll come to you.
| I'm getting my refresher training session next week.
|
| You can ship them to me. I'll take them if they're in good shape, even if
| they're locked.
|
| R.
|
| "Bob La Londe" <usenet@xxxxxxxxxxxxxxxx> wrote in message
| news:yq-dnYnsUtmY9aDeRVn-ig@xxxxxxxxxxxxxxx
|| Ok, this is number 4 or 5.
||
|| The manual says,
||
|| 1. Place a slotted screwdriver across the two J16 reset jumpers for two
|| seconds.
|| 2. Remove screwdriver.
|| 3. Enter the code 6653 (PROG) at the keypad.
|| 4. Enter Access Code (if prompted to do so).
|| 5. The keypad displays: PROGRAMMER.
||
|| Ok..
||
|| I hit the J16 jumper, walk over to the keypad, and it no longer responds.
|| After a while it comes up as system busy, then after a while longer it
| says
|| system trouble. I do the voltage check as the tech support people
suggest
|| and get the 5 volts on both sets of leads that indicate the processor is
|| locked up.
||
|| These panels are permanently locking up from trying to put them in
program
|| mode. And YES! They were functioning properly before attempting to put
|| them program mode.
||
|| They hoover little green donkey appendages. All you DMP guys who claim
| they
|| are wonderful are welcome to them. These are all just over 5 years old.
|| Planned failure?
||
|| I don't put DMPs back in their place. I'm afraid to service a DMP panel
| at
|| this point for fear that it will self destruct.
||
|| HEY DMP. Don't like what I have to say? Sue me. Everything I have had
| to
|| say about DMP is the truth.
||
|| --
|| The Security Consultant
|| Bob La Londe - Owner
|| 849 S Ave C
|| Yuma, Az 85364
||
|| (928)782-9765 ofc
|| (928)782-7873 fax
||
||
||
||
|
|
alt.security.alarms Main Index |
alt.security.alarms Thread Index |
alt.security.alarms Home |
Archives Home