Re: NetworX NX-8 Bell Output
On Fri, 29 Apr 2005 22:54:25 -0400, "Rich" <Never@xxxxxxx> wrote:
>
>The main siren terminal is needed for the system monitoring of the speaker 8
>ohms.
>
>You can use contact output 1 for a separate partition 1-8. Just check the
>blocks. The main contacts will blow for all events the other contacts will
>only be effected by the area assignment to it.
>
>
Yea, we discoverd that the only controlled outputs are the four aux on
the main board and the three on the NX-320E. So we used the high
current aux outputs on the NX-320E for the 2 partition sirens
(different partitions) and the third for a strobe output. The main
siren terminals were used for the common siren and the last strobe
light was powered from the main board through a relay on the aux 4
terminal. Seems to work fine, but a bit complex for no apparent
reason. Why couldn't this information be listed in the manual. I know,
I know, RTFM. But when you're new with the panel and you're used to
doing things one way, it can be tough with a new panel.
Thanks, eh?
Julian