Re: Napco Gemini P3200 is stupid
Subject: Re: Napco Gemini P3200 is stupid
Newsgroup: alt.security.alarms
=> geekboy0001@xxxxxxxxx <= wrote:
>Very constructive response, thanks. So, oh blessed one, how do you
>program it to work as I described?
Address 2421, bit 0 .
Will cause all Interior-1 zones to be bypassed if an exit zone is not opened
during exit delay.
Yes, you're right. The Gem-3200 is stupid. Ademco has a one-button solution to
this.
The Napco engineers made a product that does as promised, but it's so
un-intuitive, it's more trouble than it's worth. When you do manage to program
it correctly there is the greater task of explaining it to the end user. I find
their panels to be used optimally with minimal or zero user interaction.
--
-Graham