Re: DSC Maxsys PC 4020 Reporting probs.



You need to program codes in fields 320  to 353 if you use all the zones
just don't program anything for unused zones..

the information that need to be inputted is in the appendix a and b of the
installation manual page 39,40,41

if you want to send a burglar alarm from zone 1 as a perimeter alarm you
will need to program section 320 first data as 3A(for zone 1)

I know its a pain to do so but most people that install DSC use SIA

I hope it help


"Anonymoose" <none@xxxxxxxxxxxxx> a écrit dans le message de news:
ycwce.6$i1.1@xxxxxxxxxxxxxxxxxxxxxxxxx
> At my job, I work mostly with ademco panels. But on a recent remodeling
> job, our wonderful project management team decided to install one of these
> DSC panels (Not knocking them, it seems like a nice panel its just that
> I'm barely at all familiar with these). Well it just so happens that I'm
> the only tech that works with the alarm panels and they decide to throw me
> to the wolves on this one too. Anyway, sorry for blabbing.. The problem I
> am having is the DSC panel is not reporting to either of our CS-1 (Ademco
> 685's). It dials, attempts to communicate but the receiver just drops the
> call and gives one of its 11 RCVB 5555 5555 etc errors tryin to tell me it
> didn't understand the call. Now heres what I've done:
> 1. I've replaced the board, left all zone devices off
> 2. I've tested & changed the phone line to another # and cable
> 3. I've deleted all programming and left only phone #1 active
> 4. I've changed power supplies
> 5. I've dabbled in programming changing subtle settings.
> None of these work.
>
> my dept. (well, me) maintains two 685 receivers. security monitors one and
> the sheriff dept the other. I've changed phone no. 1 to to dial one
> receiver to the other and it still does it. I've also verified that both
> the receivers and the panel are set to Contact ID reporting. I now have no
> idea what else to to. I would like to resolve this as my boss is planning
> on changing out the panel to an ademco panel if its not resolved and with
> 97 zones, I think it would be a huge waste of time and taxpayer's $ to do
> this when I'm sure its prolly something right under my nose thats causing
> it. if anyone can shed some light onto this subject it would be greatly
> appreciated.
> Oh and just to be a lil more specific, there are a total of 33 alarm
> panels (all ademco other than the DSC) that report to the receivers and
> the DSC is the only one not coming thru. It was working fine and then all
> of the sudden it stopped.
> Thanks for your time and efforts.
>