Hi Glen

>Is it posssible that the timer is causing the
> crash an if so can I exclude it in the HVexclude file. The error
> reported is "runtime 13 error - type mismatch" any other
suggestions?

I think Steve would need to have a look at this.........

Have you created your HVInput.hvx and HVExclude.HVX files...????

The exclude file is used to enable reporting of events to xPL , so if you
wanted macro4 to be reported so another xPL device can do something when
macro4 runs you would remove it from the exclude file....

Frank



----- Original Message -----
From: "kirstglen1" <glen.ferguson@xxxxxxx>
To: <ukha_xpl@xxxxxxx>
Sent: Friday, March 25, 2005 9:11 PM
Subject: [ukha_xpl] Re: Homevision Help


>
>
> Hi Frank,
>
> I can turn on port C manually with no problem, it is the occurance
> of a scheduled event that turns on the prt and sets a timer that
> causes the crash. Is it posssible that the timer is causing the
> crash an if so can I exclude it in the HVexclude file. The error
> reported is "runtime 13 error - type mismatch" any other
suggestions?
>
>
> Thanks
> Glen
>
> --- In ukha_xpl@xxxxxxx, "Frank Mc Alinden"
<fmcalind@b...>
> wrote:
> > Hi Glen
> >             Think Steve C might have to answer that one....Im not
> using Port
> > C at the moment so maybe thats why i havent come across this
> error...
> > Have you created your HVInput.hvx file and also yourHVEclude.hvx
> files ???
> >
> > Frank
> >
> >
> >
> > ----- Original Message -----
> > From: "kirstglen1" <glen.ferguson@o...>
> > To: <ukha_xpl@xxxxxxx>
> > Sent: Sunday, March 20, 2005 8:23 PM
> > Subject: [ukha_xpl] Re: Homevision Help
> >
> >
> > >
> > >
> > > Thanks for all the help. Got it working fine now, the only
> problem I
> > > have is that the XplHVision plugin crashes every time the
> sprinklers
> > > come on with a "runtime13 error". The sprinklers
are programmed
> > > under port C opto-isolated through an external relay board
so I
> > > don't think it is electrical. Any ideas?
> > >
> > > Thanks
> > > Glen
> > >
> > >
> > > --- In ukha_xpl@xxxxxxx, "Frank Mc Alinden"
> <fmcalind@b...>
> > > wrote:
> > > > Hi Glen
> > > >             I had similiar issues when sending FirM
commands to
> > > Homevision
> > > > in my case i had incorrect message structure.......
> > > >
> > > > Would try what Bob suggests ..ie restarting
xPL-Hvision..if
> that
> > > doesnt fix
> > > > it copy and paste the message from xPL Monitor and post
it in
> an
> > > email to
> > > > the list so we can look at it...
> > > >
> > > > Frank
> > > >
> > > >
> > > >
> > > > ----- Original Message -----
> > > > From: "kirstglen1" <glen.ferguson@o...>
> > > > To: <ukha_xpl@xxxxxxx>
> > > > Sent: Sunday, March 20, 2005 2:39 AM
> > > > Subject: [ukha_xpl] Re: Homevision Help
> > > >
> > > >
> > > > >
> > > > >
> > > > > Hi Frank,
> > > > >
> > > > > Everything seems to be working fine from the xPL
perspective,
> > > > > however, HV is not responding to the commands. HV
sends back
> a
> > > > > confirmation message but does not perform the
message.
> > > > >
> > > > > I have the "on" actions defined in the
X-10 module summary
> window
> > > > > as "X10 A1 on" etc and I have enabled
the DDE options. I can
> turn
> > > > > the light on within HV no worries.
> > > > >  Is it significant that in the xPL monitor window
on "HV
> confirm"
> > > > > that it does not return the module name? Any other
> suggestions
> > > would
> > > > > be appreciated on how I can fix this.
> > > > >
> > > > > Thanks
> > > > > Glen
> > > > >
> > > > >
> > > > > --- In ukha_xpl@xxxxxxx, "Frank Mc
Alinden"
> > > <fmcalind@b...>
> > > > > wrote:
> > > > > > Hi Glen
> > > > > >                If you want to say when a
certain w800  x10
> > > command
> > > > > is
> > > > > > captured  by xPL and you want to run a macro
in
> > > Homevision ...just
> > > > > simply
> > > > > > hightlite the x10 command in the xPL monitor
display and
> right
> > > > > click then
> > > > > > select create Determinator..this will walk
you thru
> > > this....Have a
> > > > > look in
> > > > > > the photo section of xPL Yahoo  that might
help......The
> > > automatic
> > > > > creation
> > > > > > of a Determinator creates the input section
and you only
> need
> > > to
> > > > > add the
> > > > > > output section ie Homevision macro.....
> > > > > > Just yell out if you need more help
> > > > > > Frank
> > > > > >
> > > > > > ----- Original Message -----
> > > > > > From: "kirstglen1"
<glen.ferguson@o...>
> > > > > > To: <ukha_xpl@xxxxxxx>
> > > > > > Sent: Saturday, March 19, 2005 6:20 PM
> > > > > > Subject: [ukha_xpl] Homevision Help
> > > > > >
> > > > > >
> > > > > > >
> > > > > > >
> > > > > > > Hi all,
> > > > > > >
> > > > > > > I am quite new to all of this Xpl stuff
and was hoping
> > > someone
> > > > > could
> > > > > > > give me some help. I have Homevision pro
and a W800RF
> plugged
> > > > > into
> > > > > > > my computer. I have configured them all
as devices and
> the
> > > Xpl
> > > > > > > monitor sees the X-10 commands from the
W800. I am not
> sure
> > > how
> > > > > to
> > > > > > > configure HV to receive these commands.
The documentation
> > > talks
> > > > > > > about inputting the hvx file but I don't
know to do this
> > > except
> > > > > > > throught the X-10 import function which
I have already
> done.
> > > (by
> > > > > the
> > > > > > > way sending commands through this also
does nothing). I
> have
> > > > > xpl.ocx
> > > > > > > running and HV running at the same time.
I only have one
> > > serial
> > > > > > > interface through Com2 to HV. Is this
how I am supposed
> to do
> > > > > it? Do
> > > > > > > I need to configure this?
> > > > > > >
> > > > > > > Please help
> > > > > > >
> > > > > > >
> > > > > > > Thanks Glen
> > > > > > >
> > > > > > >
> > > > > > >
> > > > > > >
> > > > > > >
> > > > > > > xPL Links: http://www.xplproject.org.uk
> http://www.xplhal.com
> > > > > > http://www.xpl.myby.co.uk
> > > > > > > To Post a Message: ukha_xpl@xxxxxxx
> > > > > > > To Subscribe: 
ukha_xpl-subscribe@xxxxxxx
> > > > > > > To Unsubscribe: 
ukha_xpl-unsubscribe@xxxxxxx
> > > > > > > Yahoo! Groups Links
> > > > > > >
> > > > > > >
> > > > > > >
> > > > > > >
> > > > > > >
> > > > > > >
> > > > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> > > > http://www.xpl.myby.co.uk
> > > > > To Post a Message: ukha_xpl@xxxxxxx
> > > > > To Subscribe:  ukha_xpl-subscribe@xxxxxxx
> > > > > To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
> > > > > Yahoo! Groups Links
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > >
> > >
> > >
> > >
> > >
> > > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> > http://www.xpl.myby.co.uk
> > > To Post a Message: ukha_xpl@xxxxxxx
> > > To Subscribe:  ukha_xpl-subscribe@xxxxxxx
> > > To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
> > > Yahoo! Groups Links
> > >
> > >
> > >
> > >
> > >
> > >
> > >
> > >
>
>
>
>
>
> xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
http://www.xpl.myby.co.uk
> To Post a Message: ukha_xpl@xxxxxxx
> To Subscribe:  ukha_xpl-subscribe@xxxxxxx
> To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
> Yahoo! Groups Links
>
>
>
>
>
>
>
>



xPL Links: http://www.xplproject.org.uk http://www.xplhal.com http://www.xpl.myby.co.uk
To Post a Message: ukha_xpl@xxxxxxx
To Subscribe:  ukha_xpl-subscribe@xxxxxxx
To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx

xPL Main Index | xPL Thread Index | xPL Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.