Hi Frank,

First off I want to get Comfort controlling the porch light to turn
it on and off using the input from the light sensor. I haven't got
everything install and finished yet so it will be a few weeks before
I can really start to play with it. But I did manage to turn lights
on and off using the 'send xPL message' in XplHal so I know that all
works. What do you need to do to get all events from the C-Bus
network to appear as events in xPLHal?

A related question, is it possible to reconfigure C-Bus switches
dynamically. What I want to do is have some switches behave
differently depending on the time of day etc, e.g. the landing light
turn on at 20% after midnight.

Thanks
Rob

--- In ukha_xpl@xxxxxxx, "Frank Mc Alinden" <fmcalind@b...>
wrote:
> Hi Rob
>             Let us know how things go with xPL-Cgate...John and I
are using
> it ....Hoping at some stage being able to control the cbus lites
with an
> elcheapo remote......
> Frank
>
>
> ----- Original Message -----
> From: "Rob Kearns" <robkearns@y...>
> To: <ukha_xpl@xxxxxxx>
> Sent: Thursday, September 23, 2004 6:43 AM
> Subject: [ukha_xpl] Re: xPL C-Gate
>
>
> >
> >
> > Thanks John, thats exactly what is was.
> >
> > Regards
> > Rob
> >
> > --- In ukha_xpl@xxxxxxx, "John B"
<home-automation@j...>
> > wrote:
> > > Hi Rob,
> > >
> > > > I'd like to use xPL C-Gate but can't even get C-Gate
running.
> > When I
> > > > start the Console version of C-Gate I get the following
messages:
> > > >
> > > > Clipsal C-Gate(TM) v1.5.2   (build 1098)
> > > > Hardware key: Key initialize failed (DRIVER NOT
INSTALLED)
> > > > License file not found.
> > > > Total network licenses: 0
> > >
> > > The above messages are normal - C-Gate should work fine with
1
> > network without a license installed.
> > >
> > > > 20040921-220750 800 cgate C-Gate started.
> > > > 20040921-220751 911 1 Can't open C-Bus interface (no
such
port):
> > COM1
> > >
> > > I've seen the above error on my own setup - kept saying that
COM1
> > didn't exist, and I tracked it down to the version of Java that
was
> > installed.
> > >
> > > When you install C-Gate, it offers to install Java for you -
if
you
> > let it install Java then things should be OK.
> > >
> > > I had the latest version of Sun's JRE already installed, so
> > said "No" when asked by C-Gate if I wanted to install
Java, and
then
> > I got the "no such port" error.  Reinstalled C-Gate,
and let it
> > install it's own version of Java, and things worked fine.
> > >
> > > Other than that, I'm not sure what else to suggest.
> > >
> > > If you don't have any success, you could try asking on the
C-Bus
> > Forums at www.cbusforums.com - I'm sure other C-Gate users will
have
> > experienced the same problem.
> > >
> > > HTH,
> > >
> > > John
> >
> >
> >
> >
> > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> http://www.xpl.myby.co.uk