Re: xPL-FirM-Schema



Fair enough.  I don't claim to be an xpl expert - I'd hoped that one who is
would have replied to your initial request.

Mal



----- Original Message -----
From: "Frank Mc Alinden" <fmcalind@xxxxxxx>
To: <ukha_xpl@xxxxxxx>
Sent: Tuesday, September 14, 2004 11:56 AM
Subject: Re: [ukha_xpl] xPL-FirM-Schema


> Hi Mal
>
> > I had a quick look at the schemas in the docs, but it seems there
isn't
> > suitable existing one that you could use.  The remote.basic is
the
> closest,
> > but requires key names, with the zone being optional.  You of
course
don't
> > have any key names
>
> I have based my schema similiar to what Tony did for my probe
kit.........
>
> > While you can certainly set the zone for transmission, via xpl,
I'm not
> sure
> > how the receive will work - if Homevision doesn't request the
zone, does
> > that means that the zone sent in the xpl_stat message may be
wrong?
>
> The zone received status message would only be sent if Homevision /
usb
uirt
> requested it .......
>
> > One little nitpicking detail - other schemas (like the config
requests)
> use
> > command=request - your Firm.basic schema has current=request.  I
wonder
if
> > it should change, just to be consistant?
>
> Nit pick away ...i want to try and get it right first time.....
> If you look at the zoning schemas when requesting a device ie temp
sensor
it
> sends a current=request...???????
>
> Frank
>
> ----- Original Message -----
> From: "Mal Lansell" <mlansell@xxxxxxx>
> To: <ukha_xpl@xxxxxxx>
> Sent: Tuesday, September 14, 2004 8:40 PM
> Subject: Re: [ukha_xpl] xPL-FirM-Schema
>
>
> > Well you are using you're own schema - so I guess you can send
whatever
> you
> > need - in this case it's just a zone number.
> >
> > I had a quick look at the schemas in the docs, but it seems there
isn't
> > suitable existing one that you could use.  The remote.basic is
the
> closest,
> > but requires key names, with the zone being optional.  You of
course
don't
> > have any key names.
> >
> > While you can certainly set the zone for transmission, via xpl,
I'm not
> sure
> > how the receive will work - if Homevision doesn't request the
zone, does
> > that means that the zone sent in the xpl_stat message may be
wrong?
> >
> > One little nitpicking detail - other schemas (like the config
requests)
> use
> > command=request - your Firm.basic schema has current=request.  I
wonder
if
> > it should change, just to be consistant?
> >
> > Mal
> >
> >
> >
> > ----- Original Message -----
> > From: "Frank Mc Alinden" <fmcalind@xxxxxxx>
> > To: <ukha_xpl@xxxxxxx>
> > Sent: Tuesday, September 14, 2004 11:18 AM
> > Subject: Re: [ukha_xpl] xPL-FirM-Schema
> >
> >
> > > Hi Mal
> > >             Thanks for replying........
> > > Firstly FirM was designed as an "Addon" for
Homevision ....and
> Homevision
> > > encodes and decodes ALL ir signals ...all FirM does is 1:
direct the
> > > transmitted ir (from homevision  / usb uirt)
> > > to the required zone........2: Informs  Homevision when
requested
which
> > zone
> > > sent ir...........
> > >
> > > > 1) have the FirM controller send an xpl_trig message,
containing the
> > zone
> > > > and the IR message when IR is received from the rx
unit.
> > >
> > > FirM Can only give Zone info only ....Homevision / usb uirt 
receive
ir
> > > message and decode....
> > > Unable to send a trig message due to current FirM
hardware......It
uses
> 3
> > > pins (bcd) for zone identification and will update the pins
when ir is
> > > received but relies on Homevision / usb uirt to read the
pins when
> > required
> > > .....Homevision  / usb uirt may not require  zone
info.........
> > >
> > > > 2) Send an xpl_cmnd to FirM containing the zone and IR
message to
send
> > > when
> > > > you want to transmit.
> > >
> > > Hopefully thats what im doing with the xpl message
below...........the
> > > zoning schemas in the xpl docs seem to confuse me .....
> > >
> > > > > > xpl-cmnd
> > > > > > {
> > > > > > hop=1
> > > > > > source= xpl-xplhal.mainpc
> > > > > > target=aec-FirM.mainpc
> > > > > > }
> > > > > > FirM.basic
> > > > > > {
> > > > > > zone=1
> > > > > > }
> > >
> > > Thanks
> > > Frank
> > >
> > >
> > >
> > >
> > > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> > http://www.xpl.myby.co.uk
> > > To Post a Message: ukha_xpl@xxxxxxx
> > > To Subscribe:  ukha_xpl-subscribe@xxxxxxx
> > > To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
> > > Yahoo! Groups Links
> > >
> > >
> > >
> > >
> > >
> >
> >
> >
> >
> > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> http://www.xpl.myby.co.uk
> > To Post a Message: ukha_xpl@xxxxxxx
> > To Subscribe:  ukha_xpl-subscribe@xxxxxxx
> > To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
> > Yahoo! Groups Links
> >
> >
> >
> >
> >
>
>
>
>
> xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
http://www.xpl.myby.co.uk