Not being familiar with the intimate details of FirM, I'm not quite sure
what is meant by telling FirM to "setup" for an IR zone, so maybe
what
follows is off target, but couldn't you just:
1) have the FirM controller send an xpl_trig message, containing the zone
and the IR message when IR is received from the rx unit.
2) Send an xpl_cmnd to FirM containing the zone and IR message to send when
you want to transmit.
As far as I can tell, what you put into your schema is completely up to
you,
so long as it conforms to the name=value structure.
Mal
----- Original Message -----
From: "Frank Mc Alinden" <fmcalind@xxxxxxx>
To: <ukha_xpl@xxxxxxx>
Sent: Tuesday, September 14, 2004 10:27 AM
Subject: Re: [ukha_xpl] xPL-FirM-Schema
> Anybody care to comment ???.....
>
> Also is the below message correct for a reply to a "Which
Zone" is
sending
> ir request ..???
>
> xpl-stat
> {
> hop=1
> source= aec-FirM.mainpc
> target=*
> }
> FirM.basic
> {
> zone=1...........8 (can be 1 to 8)....
> }
> Many thanks
> Frank
>
> ----- Original Message -----
> From: "Frank Mc Alinden" <fmcalind@xxxxxxx>
> To: <ukha_xpl@xxxxxxx>
> Sent: Monday, September 13, 2004 8:02 PM
> Subject: [ukha_xpl] xPL-FirM-Schema
>
>
> > Hi All
> > Decided to make a start on xPLling FirM and would like to
clarify
> a
> > few things.....
> > Still not quite sure how the schemas should be done........
> > Below is a copy of a command to my Probe Kit , Im using this as
a
temple
> > for my FirM Kit , below that is what im hoping to use for
FirM....Comments
> > please......
> >
> >
*************************************************************************
> > This is a command to Probe Hub
> >
> > xpl-cmnd
> > {
> > hop=1
> > source= xpl-xplhal.mainpc
> > target=aec-probe.mainpc
> > }
> > probe.basic
> > {
> > zone=lounge
> > probe=all
> > }
> >
*********************************************************************
> > This is a command to FirM to tell it to setup for ir zone 1 based
on the
> > Probe kit schema........
> >
> > xpl-cmnd
> > {
> > hop=1
> > source= xpl-xplhal.mainpc
> > target=aec-FirM.mainpc
> > }
> > FirM.basic
> > {
> > zone=1
> > }
> >
***********************************************************************
> > Reply to setup for zone 1
> >
> > xpl-stat
> > {
> > hop=1
> > source= aec-FirM.mainpc
> > target=*
> > }
> > FirM.confirm
> > {
> > zone=1
> > }
> >
**************************************************************************
> > Thats the transmit side of things.Now the receive side of
> things.......When
> > the USB UIRT receives an ir signal it can if it wishes request
from
FirM
> > Serial which zone the signal came from hopefully as
follows.......
> >
************************************************************************
> > xpl-cmnd
> > {
> > hop=1
> > source= xpl-xplhal.mainpc
> > target=aec-FirM.mainpc
> > }
> > FirM.basic
> > {
> > current=request
> > }
> >
*************************************************************************
> > Thanks
> > Frank
> >
> >
> >
> >
> > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> http://www.xpl.myby.co.uk
> > To Post a Message: ukha_xpl@xxxxxxx
> > To Subscribe: ukha_xpl-subscribe@xxxxxxx
> > To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> > Yahoo! Groups Links
> >
> >
> >
> >
> >
>
>
>
>
> xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
http://www.xpl.myby.co.uk
> To Post a Message: ukha_xpl@xxxxxxx
> To Subscribe: ukha_xpl-subscribe@xxxxxxx
> To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> Yahoo! Groups Links
>
>
>
>
>
xPL Main Index |
xPL Thread Index |
xPL Home |
Archives Home
|