Re: Re: xPLComfort hanging




Hi Rob,

> I'm still having no luck :-(
>
> Should I expect to see a LU01 in the log after sending a keypad
> command?

You'll only see a LU command when xPL Comfort fires up initially - as
that's when it logs in.

>
> I'm using ACE-Comfort to test my setup and after logging in, if I hit
> the # key I get a "there are no messages" from the UCM. But
in
> xPLComfort if I send a 0C digit I get no response and nothing in the
> log either.
>
> If you have time could you add logging for all messages sent and
> received?

All communications between xPL Comfort and the UCM are already logged - so
if it's not listed in the log, then it's not being send out to the UCM.

I've just sent the following message to my Comfort:

xpl-cmnd
{
hop=1
source=xpl-xplhal.mercury
target=johnb-comfort.jupiter
}
control.basic
{
device=keypad
type=digit
current=0C
}

And got the following in the logs:

21/Oct/2004 21:57:48 Sending to comfort: KD0C
21/Oct/2004 21:57:48 Received: OK

Which looks correct to me.

What are you using to send your xPL message?

Regards,

John