The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024

Latest message you have seen: Re: Suggestion for xPLOWTemp


[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

W800 Service Updated


  • Subject: W800 Service Updated
  • From: "Mal Lansell" <mlansell@xxxxxxxxxxxxxx>
  • Date: Fri, 17 Dec 2004 21:05:57 -0000



I've updated the W800RF32 service to handle messages from X10
security RF devices

Unfortunately, the security devices are intended to be used only with
their base stations, rather than as general X10 controls.  The
messages they send have no relation to any of the standard X10
functions.  Therefore, the service sends security messages using the
remote.basic schema (standard X10 RF commands are still sent using
X10.basic).

It uses two of the remote.basic message body elements -
keys=num1 (where num1 is the keycode sent by the device 0-255)
device=num2 (where num2 is the id of the security device 0-255)

This should be sufficient to distinguish between controllers, and to
use their commands to trigger determinators etc.

Mal








xPL Main Index | xPL Thread Index | xPL Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.