another question,
do i need to go through all the events (xAPRaw, xAPStart, xAPCheck,
xAPEnd) to process a message? or can i just have 1 of them in my app
(like just xAPCheck since that seems like what i want)? thanks
--- In xap_automation@xxxxxxx, "rleong1" <rleong1@...>
wrote:
>
> gotcha. thanks to both Kevins for your quick replies.
>
> --- In xap_automation@xxxxxxx, "turner228" <kevin@>
wrote:
> >
> > Something not quite right with my reply, so try again...
> >
> > > is there a subuid limit? up to "FF"?
> >
> > From the V1.2 Protocol definition :-
> >
> > The UID is generated as an upper case ASCII hex number,
comprising nn
> > dd dd ss where nn is the xAP network and domain identifier (FF by
> > default), dd dd is the unique device identifier and ss is a
subaddress
> > node within the device. For all elements of the UID, the values
FF
and
> > 00 are reserved for future use. Sub addressing is explained in
more
> > detail below.
> >
> > http://www.xapautomation.org/index.php?title=Protocol_definition
> >
> > HTH
> >
> > KevinT
> >
>