RE: [OT] Network link lights


  • Subject: RE: [OT] Network link lights
  • From: "Dean Barrett" <dean@xxxxxxxxx>
  • Date: Wed, 26 Jul 2006 09:48:45 +0100

Put a cable tester on it - all check out ok.
=20
Have changed leads/ports/wall outlets and still no joy :(
=20
=20
=20
=20
=20
_____=20=20

From: ukha_d@xxxxxxx [mailto:ukha_d@xxxxxxx] On Behalf Of
Ian Lowe
Sent: 26 July 2006 09:15
To: ukha_d@xxxxxxx
Subject: RE: [ukha_d] [OT] Network link lights



Test the cabling =96 that sounds exactly what you get when you have pins 1
=
and
2 wired correctly, but pins 3 and 6 are on separate pairs.

Individual NICs have a greater or lesser tolerance for this.

This happens if you use an ISDN patch lead (so, all wired straight through)
or a fubar=92ed patch lead with the colours not done correctly.

I.

_____=20

From: ukha_d@yahoogroups. <mailto:ukha_d%40yahoogroups.com>
com
[mailto:ukha_d@yahoogroups. <mailto:ukha_d%40yahoogroups.com>
com] On Behal=
f
Of
Dean Barrett
Sent: 26 July 2006 08:52
To: ukha_d@yahoogroups. <mailto:ukha_d%40yahoogroups.com>
com
Subject: [ukha_d] [OT] Network link lights

I'm having an absolute mare getting a Dell Poweredge SC420 (one of their =
=A399
servers) to connect to our network.

I know a few people bought them here and wondered how they got on.

We have one already that was full price this is on network ok - but the new
one just wont connect the link lights on the back are on - though i've
noticed its one yellow and one red - is this correct ???

The existing server is the same and a Dell Optiplex SX280 is the same - but
all other PCs/Dells are one yellow and one green.

All these machines have Broadcom Gigabit ethernet on board adaptors.

The new one just keeps saying limited or no connection - on the switch the
10/100 and FDX/COL lights are illuminated so im sure this means its on

Any suggestions greatly appreciated - i tried new cables new ports on the
switch etc., but the bugger just will not connect.

Dean.

[Non-text portions of this message have been removed]