Chris,
=20
Not sure exactly what you are intending to use this cable for but from your
comment on 6 runs per position I guess you are talking about CAT5E for
general use i.e.data,voice,video etc..=20
=20
If this is the case then use standard CAT5E and if it is buried then
condui=
t
it. Don=92t run it in the same conduit as the mains circuits, maintain
separation for different cable types (especially mains), support the cable
properly and you won=92t go far wrong.
=20
If however you are talking about installing C-Bus then use the pink mains
sheath rated cable. It won=92t cost you a lot=85=85 last two jobs were a
5,=
500 sq
ft house with over 50 switches plus motion sensors etc. even with
redundanc=
y
in case of damaged cables we used less than three boxes of C-Bus
Cat5=85.th=
e
other a 3000 sq foot used less than a box. I am currently planning a hotel
install covering a Spa and all the public areas estimate is that we will
us=
e
around 8 boxes.=20
=20
If you run ordinary CAT5E into a consumer unit containing 240V AC then you
are almost certainly at odds with the regs. You will have problems getting
=
a
cert for your electrics unless you use a well dodgy sparks.=20
=20
HTH
Mick
=20
=20
=20
_____=20=20
From: ukha_d@xxxxxxx [mailto:ukha_d@xxxxxxx] On Behalf Of
Chris Hunter
Sent: 29 April 2006 17:27
To: ukha_d@xxxxxxx
Subject: [ukha_d] C-Bus / Cat5e
=20
'looking to buy plenty of cable ... C-Bus shop sells C-Bus cable at=20
about 70GBP per 305m ... but I had in my mind that Cat-5e would come at=20
a little over 20GBP per 305m ... so, just wondered what people have been=20
paying ... and where they go for it !
haven't worked-out yet how many runs to make, per postion ... some seem=20
to go as high as six !
Chris
"http://www.automatedhome.co.uk"http://www.automatedhome.co.uk
SPONSORED LINKS=20
HYPERLINK
"http://groups.yahoo.com/gads?t=3Dms&k=3DHome+repair+improvement&w1=3DHome+=
repair+
improvement&w2=3DComputer+stuff&w3=3DHigh&w4=3DImprovement&c=3D4&s=3D76&.si=
g=3DTcERUCDPQ
cJLbg9mtvQGJQ"Home repair improvement=20
HYPERLINK
"http://groups.yahoo.com/gads?t=3Dms&k=3DComputer+stuff&w1=3DHome+repair+im=
proveme
nt&w2=3DComputer+stuff&w3=3DHigh&w4=3DImprovement&c=3D4&s=3D76&.sig=3DplS9-=
eUUfaBXyLVFT8
7AJg"Computer stuff=20
HYPERLINK
"http://groups.yahoo.com/gads?t=3Dms&k=3DHigh&w1=3DHome+repair+improvement&=
w2=3DComp
uter+stuff&w3=3DHigh&w4=3DImprovement&c=3D4&s=3D76&.sig=3Db5d547gPx7eFWNGqX=
QCl7A"High=20
HYPERLINK
"http://groups.yahoo.com/gads?t=3Dms&k=3DImprovement&w1=3DHome+repair+impro=
vement&
w2=3DComputer+stuff&w3=3DHigh&w4=3DImprovement&c=3D4&s=3D76&.sig=3DO6pw_ora=
tTOwep2G_91fI
Q"Improvement=20
=20
=20
=20
_____=20=20
YAHOO! GROUPS LINKS=20
=20
* Visit your group "HYPERLINK
"http://groups.yahoo.com/group/ukha_d"ukha_d"
on the web.
=20=20
* To unsubscribe from this group, send an email to:
HYPERLINK
"mailto:ukha_d-unsubscribe@xxxxxxx?subject=3DUnsubscribe"ukha_d-uns=
ubs
cribe@xxxxxxx
=20=20
* Your use of Yahoo! Groups is subject to the HYPERLINK
"http://docs.yahoo.com/info/terms/"Yahoo!
Terms of Service.=20
=20
_____=20=20
--
No virus found in this incoming message.
Checked by AVG Free Edition.
Version: 7.1.385 / Virus Database: 268.4.6/323 - Release Date: 24/04/2006
--=20
No virus found in this outgoing message.
Checked by AVG Free Edition.
Version: 7.1.385 / Virus Database: 268.4.6/323 - Release Date: 24/04/2006
=20
[Non-text portions of this message have been removed]
UKHA_D Main Index |
UKHA_D Thread Index |
UKHA_D Home |
Archives Home
|