Re: C-Bus Pascal Automation Controller (PAC) - Min Review
Mike Griffiths wrote:
> It is brilliant at "who is in the house what is the temp should I
turn
> the lights on
>
Hi Mike - have you got the PAC to be able to read C-Bus temp sensors ? - I
haven't tried it but I was reading this line in the PICED docs ..
4.15.16 GetUnitParameter Function.....
....returns the value of a C-Bus unit parameter. This is *not*
applicable for use with the Pascal Automation Controller
.. the parameter types are ..
1 ptTemperature Temperature C or F Temperature Sensor
2 ptLightLevel LightLevel (Lux) Light Level Sensor
Haven't got to far into this so maybe there's another way....
C-Bus sensors do not broadcast their current value on C-Bus, instead
they have to be interrogated for current value (to save bandwidth)