The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024

Latest message you have seen: RE: MCE (again)


[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: House Rewiring (Data and Power)



How about failure strategies ... when something blows, will
everything go down with it ?   Lights & sockets ... .   And how will
you deal with emi / emc ?

CBUS uses a specially control/signal cable, of course ... and needs
to be kept separate, as per their literature ...

Telephone, Cable, aerial (terrestrial & satellite) ... ?


Chris


On 28 Dec 2005, at 14:01, Andy Laurence wrote:

> I've been off the list for quite some time, so apologies if I've
> missed anything.  Fortunately, things are now slowing down again, and
> the pending purchase of a new home promises lots of HA fun.  This
> time, I'll do it properly!  I've got a couple of months to start
> planning, so here goes my first area to tie up.  The house will need
> rewiring, so I want to ensure I get everything right first time.
> Last time, I didn't get the front room done, which scuppered nearly
> every project I attempted!
>
> Firstly, power cabling.  I think it would be sensible to wire the
> lighting to a single point, so I can replace automation units as/when
> required.  How have people done this?  Have you run a seperate ring
> to each light, and terminated all the rings at a central location?
> Basically, I'd like to be able to (for example) run LD11s, and later
> upgrade to CBUS without having to lay more cables.  The cabling I do
> must cover every possibility.  I won't start another X10 vs CBUS
> thread here!
>
> Secondly, there's the data/signal cabling.  I'll need Ethernet,
> audio, video, low voltage power, and IR for starters.  No doubt
> serial connections will appear at some point too.  I'd say all that
> can be covered by CAT5, coax, and speaker cable.  POE adapters can
> sort out my power requirements over CAT5 where unexpected, though I
> will run some power cable for 12vdc at each outlet.
>
> My current thoughts on what to run are as follows....
>
> Lounge:
> 2x CAT5, speaker and 1x 12vdc to each corner
> 6x CAT5, 1x 12vdc and 1x Coax to possible TV locations
>
> Dining Room:
> 2x CAT5, speaker and 1x 12vdc to each corner
> 2x CAT5, and 1x Coax to possible TV locations
>
> Sun lounge:
> 2x CAT5, 2x speaker, and 1x 12vdc
>
> Downstairs bathroom:
> 2x CAT5, 2x speaker, and 1x 12vdc
>
> Kitchen:
> 4x CAT5, 1x speaker, and 1x 12vdc to each corner
>
> Hallway:
> 1x CAT5 and 1x 12vdc at each end
>
> Landing:
> 1x CAT5 and 1x 12vdc at each end
>
> 3x Bedrooms:
> 1x CAT5, 1x speaker, and 1x 12vdc to each corner
> 2x CAT5, and 1x Coax to possible TV locations
>
> Bathroom:
> 4x CAT5, 2x speaker, 1x coax, and 1x 12vdc
>
> What have I missed?  Finally, what's recommended for the audio side
> of things?  I'm thinking about an amplifier hidden somewhere, on a
> switchable power supply, and speaker cable from that to the speakers
> in each room.  That way, the speakers in each room could be turned
> on/off, so sound could be on in one room, and not another.  Would I
> be better off trying to locate the amplifier in the room (shorter
> speaker cables), or locating them all centrally (better
> maintenance)?  Answers on a postcard....
>
> Cheers,
> Andy (glad to be back)
>
>
>
>
>
>
>
>
>
>
> SPONSORED LINKS
> Home repair improvement	Computer stuff	High
> Improvement
>
> YAHOO! GROUPS LINKS
>
>  Visit your group "ukha_d" on the web.
>
>  To unsubscribe from this group, send an email to:
>  ukha_d-unsubscribe@xxxxxxx
>
>  Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
>
>



[Non-text portions of this message have been removed]




UKHA_D Main Index | UKHA_D Thread Index | UKHA_D Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.