Gareth
Suggestion if the voltage on the power switch is extra low voltage
then mount a 3.5mm socket in a suitable location on th xbox and wire it in
parallel with the power switch..Put a 3.5mm plug on the 2 wire coming from
the dry contacts of your comfort board...
Doing this allows you to remove your xbox easily if needed without
disconnecting any wires....
HTH
Frank
----- Original Message -----
From: "Gareth Cook" <g@xxxxxxx>
To: <ukha_d@xxxxxxx>
Sent: Monday, August 22, 2005 8:13 PM
Subject: Fw: [ukha_d] XBOX - HA for Power ?
It's my lack of understanding of electronics :-)
Gareth Cook
Tools and Process Architect
IBM SWG Sales - Lotus Park, Staines, TW18 3AG
Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
AIM Chat : TheBoyG - MSN Chat : chat@xxxxxxx
email: g@xxxxxxx
----- Forwarded by Gareth Cook/UK/IBM on 22/08/2005 11:12 -----
Discussion
Main Topic
ukha_d@xxxxxxx
Today 10:58
.
Subject:
.
RE: [ukha_d] XBOX - HA for Power ?
.
Category:
Not sure what you mean:
On the relay - you just use the dry contacts. Comfort supplies the correct
voltage etc to drive the coil in the relay. The relay board I have is
rated up to 5A (low voltage) - so plenty for doing what you want.
Paul.
> -----Original Message-----
> From: ukha_d@xxxxxxx [mailto:ukha_d@xxxxxxx] On Behalf
Of
> Gareth Cook
> Sent: 22 August 2005 10:48
> To: ukha_d@xxxxxxx
> Subject: Fw: [ukha_d] XBOX - HA for Power ?
>
> Okies, wasnt sure if it would deliver more voltage than would be
required.
> I did think I might have needed a 12v > 3v relay
>
> This should be good - first CBUS enabled XBOX ? :-)
>
> G.
>
> Gareth Cook
> Tools and Process Architect
> IBM SWG Sales - Lotus Park, Staines, TW18 3AG
> Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
> AIM Chat : TheBoyG - MSN Chat : chat@xxxxxxx
> email: g@xxxxxxx
>
>
> ----- Forwarded by Gareth Cook/UK/IBM on 22/08/2005 10:47 -----
>
> Discussion
> Main Topic
>
> ukha_d@xxxxxxx
> Today 10:43
>
> .
> Subject:
> .
> RE: [ukha_d] XBOX - HA for Power ?
> .
> Category:
>
>
>
> Definitely do it via the Comfort relay board.
>
> Paul.
>
> > -----Original Message-----
> > From: ukha_d@xxxxxxx [mailto:ukha_d@xxxxxxx] On Behalf
> Of
> > Gareth Cook
> > Sent: 22 August 2005 09:14
> > To: ukha_d@xxxxxxx
> > Subject: Fw: [ukha_d] XBOX - HA for Power ?
> >
> > Pretty much what I thought. Now the question is : can I wire it
direct
> to
> > a Comfort output, or via the relay board (which I have)....
> >
> > G.
> >
> > Gareth Cook
> > Tools and Process Architect
> > IBM SWG Sales - Lotus Park, Staines, TW18 3AG
> > Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
> > AIM Chat : TheBoyG - MSN Chat : chat@xxxxxxx
> > email: g@xxxxxxx
> >
> >
> > ----- Forwarded by Gareth Cook/UK/IBM on 22/08/2005 09:01 -----
> >
> > Discussion
> > Main Topic
> >
> > ukha_d@xxxxxxx
> > Yesterday 14:22
> >
> > .
> > Subject:
> > .
> > Re: [ukha_d] XBOX - HA for Power ?
> > .
> > Category:
> >
> >
> >
> > I can't remember the exact voltage, but it's either 5v or 12v.
> > It works just the same as a standard ATX PC power supply, the
Xbox psu
> > is 'on' all the time, and when you push the power button, the
> > motherboard starts up.
> > So basically shorting out the two connections to the 'on' button
> > (without adding any voltage) would start the Xbox just fine...
> >
> > > Here's a thought.
> > >
> > > I want another media player and have been looking at
dvd/divx
players
> > > with
> > > network support - but they all seem a little flakey, whereas
XBMC
just
> > > works. But the problem with the XBOX is the on/off - you
have to
press
> > > the
> > > front switch and the remote cant do it (without an awkward
mod). I
> would
> > > be siting the XBOX in Node0.
> > >
> > > So how about this - I wonder what voltage the power switch
at the
> > > front is
> > > ? I'm curious to know if this can be wired into a Comfort
output
(not
> > > sure
> > > if it would need to go through my relay or not - prob bot)
direct to
> the
> > > switch on the front of the xbox.
> > >
> > > I can then program a button on the CBUS DLT in the lounge to
tell
> > Comfort
> > > to toggle the power. Not quite as good as a remote but at
least it's
a
> > > switch in the same room !
> > >
> > > Comments ?
> > >
> > > G.
> >
> >
> >
> >
> >
> >
> >
> >
> > Yahoo! Groups Links
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> > Yahoo! Groups Links
> >
> >
> >
> >
> >
>
>
>
>
>
> Yahoo! Groups Links
>
>
>
>
>
>
>
>
>
>
>
>
> Yahoo! Groups Links
>
>
>
>
>
UKHA_D Main Index |
UKHA_D Thread Index |
UKHA_D Home |
Archives Home
|