Richard,
Interesting idea.. I had thought of that but "assumed" that the
light would
flash on at full brightness momentarily... not very SWMBO friendly if it
does
it at 6am every morning. Now after you saying that I'm wondering if that
because of the soft start the, light won't have had time to actually come
on
before it received the "off" command.
I've just Remote Desktop'd into my home PC and set it up.. I'll see what
happen tomorrow morning :)
Thanks
Marcus
> We have a similar situation using PIR at night to turn on the lights
> (via Comfort in our case but that's pretty much immaterial). Had the
> same issue with the next morning/day in the hall or landing when
> light was needed and using the wallswitch it just goes onto the night
> level of 20%.
>
> Solved it by doing a 'reset' in the morning. Sending preset 100% and
> then unit off in quck succession means that you then get 100% when
> someone uses the manual wall switch. We never actually notice this
> brief reset.
>
> Regards
>
> Richard