I'd think you'd only need a cross over. I'd be suprised if it would use
cts/rts
so try a cable that is
3--->2 (Tx-Rx)
2--->3 (Rx-Tx)
5-->5 (gnd)
I'd also enable local echo within hyperterminal to see what you are typing
(assuming it's not echoed back)
Shout if this doesn't work
----- Original Message -----
From: "christopher purves" <CHRIS_PURVES@xxxxxxx>
To: <ukha_d@xxxxxxx>
Sent: Friday, November 05, 2004 2:45 PM
Subject: [ukha_d] Help Needed! Serial Communication with BT Revelation CLU
>
> Hi Guys,
>
> I wonder if any of you can offer some advice on the following problem.
>
> I have a BT revelation in which I have installed a call logger unit.
The
CLU
> has a serial (male) 9 pin output. The BT manual quotes 1200 baud 8
bits no
> parity but little else in the way of help. I can see a volatge(12v or
so)
> between pins 2 and 3.
>
> I have so far failed to get anything from the unit. I am assuming I
need
to
> use a null modem cable to attach to pc. I have tried hyperterminal and
a
> shareware serial port monitor utility but to no avail.
>
> Any ideas anyone ? - I have no idea if it implements handshaking by
the
way.
>
> I'm not even sure it its sending anything. Other than the CLU the
revelation
> works perfectly.
>
> Chris
>
>
>
>
>
>
>
> Yahoo! Groups Links
>
>
>
>
>
>
>
UKHA_D Main Index |
UKHA_D Thread Index |
UKHA_D Home |
Archives Home
|