The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024


[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: CM11 - how to clear the memory ?? - thx


  • Subject: Re: CM11 - how to clear the memory ?? - thx
  • From: "egelbeertje" <r_d_k@xxxxxxxxxxx>
  • Date: Tue, 28 Dec 2004 08:33:08 -0000



Hi Li,

Ok, resetting the dawn dusk values to 10 solved the problem - thx for
that - I also noticed the US version (1.42) sets it by default to 50
as you mentioned, the European version (also 1.42) runs it at 25 by
default.

rgds Rob.

--- In ukha_d@xxxxxxx, "K. C. Li" <li@l...> wrote:
> On Mon, 27 Dec 2004, egelbeertje wrote:
>
> > Been fiddling with it over the weekend and suddenly
got "Insufficient
> > Memory in the Interface" error. Can't get it cleared and
can't
upload
> > new timers.
>
> ActiveHome appears to set the default dawn and dusk resolution
rather high
> at 50. That parameter controls the pairs of dawn and dusk times
calculated
> based on the longitude and latitude set. The generated values are
then
> preloaded into the CM12U to account for the sunrise/sunset variation
> throughout the year. They occupy the same 1kB EEPROM space as
timers and
> macros so the more dusk/dawn pairs, the less for everything else. A
> suggested value of 12 or less should be sufficient for most needs.
>
> To change the number of dusk and dawn values generated, do the
following:
>
> Select menu options
>   Tools -> Statistics -> Resolution
>
> Then change the Timer Resolution to a smaller number and press
"OK".
>
> The Statistics screen shows the number, day range and times of
dusk/dawn
> pairs generated.
>
> > All advise welcome (obiously I already left it unplugged
overnight
> > without batteries but to no avail.)
>
> The CM12U's EEPROM memory can also be cleared by the following:
>
> Tools -> Clear Interface Memory
>
> Merry Christmas and a Happy New Year!
>
> Regards,
>
> Kwong Li
> li@l...
> Laser Business Systems Ltd.
> http://www.laser.com
> http://www.cbus-shop.com






UKHA_D Main Index | UKHA_D Thread Index | UKHA_D Home | Archives Home