Fw: Re: Grounding IR cabling


  • Subject: Fw: Re: Grounding IR cabling
  • From: Gareth Cook <g@xxxxxxxxxx>
  • Date: Fri, 10 Dec 2004 10:16:03 +0000


Well, I've changed the wiring to the IR Receiver in the lounge - and
that's pretty much sorted it. That was part of a block of 12 CAT5 going to
the lounge, and alongside whatever else was there in the cavity.

The PSU used is the one supplied by LA for the Xantech block. I think it's
regulated - mebe Phil can shed some light on that.

I would just like to see what the best way of grounding the shielded
cabling is.

G.

Gareth Cook
SWG EMEA North Account Manager
IBM SWG - BTE Office - Lotus Park, Staines, TW18 3AG
Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
AIM Chat : TheBoyG - MSN Chat : chat@xxxxxxx
email: g@xxxxxxx


----- Forwarded by Gareth Cook/UK/IBM on 10/12/2004 10:06 -----

Discussion
Main Topic

"rectorydp" <dpullen@xxxxxxx>
Today 09:56

.
Subject:
.
[ukha_d] Re: Grounding IR cabling
.
Category:





Gareth

I ddn't see the message where you talked about the problem with your
IR distribution so I am not sure if this will be helpful or not. I
gather from what you say below that you have emitters that are
constantly on. What power supplies are you using? I didn't have any
problems with long runs of CAT5 between IR kit (up to about 35m) but I
did have a problem like this with an unregulated power supply. As soon
as I changed to a regulated supply the problem went away.

BR
David


--- In ukha_d@xxxxxxx, Gareth Cook <g@u...> wrote:
> I'm going to rewire all the IR receivers this weekend - the screened
CAT5
> turned up (very fast from minitran)
>
> I'm using a Xantech dist. block with Buffalo receivers. I'm assuming I
> connect the sleeve earth wire at the dist. module (at node 0), and do
> nothing with the other end where all the receivers are. But, I can
connect
> it to the cage, but the cage isnt earthed. Then will it follow true I
> should earth the cage ? Maybe a plug with the just the earth lead
> connected and plugged into the mains (ala wrist strap) ??
>
> Hopefully this screened cable will get rid of this cursed
constant-on the
> IR system has.
>
> G.
>
>  Gareth Cook
>  SWG EMEA North Account Manager
>  IBM SWG - BTE Office - Lotus Park, Staines, TW18 3AG
>  Office: +44 (0)1784 445166 - Mobile: +44 (0)7980 445166
>  AIM Chat : TheBoyG - MSN Chat : chat@g...
>  email: g@xxxxxxx
>
>
>
> [Non-text portions of this message have been removed]