The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: Caller ID unit.



On Wed, 2003-07-02 at 10:03, Ian Davidson wrote:

> The Mitel chips output is not async but is clocked out with the start
> and stop bits removed (just the data bits). A small micro could easily
> decode this but it is not suitable for the input of a PC RS232 even
when
> level converted. The only solution would be to but a small micro in
> there (read PIC) to re-insert the start and stop bits and then level
> convert but it is probably not worth it.

My reading of the data sheet was that the chip works in two modes, the
one you describe above, and one that is suitable to connect to a PC
after it has been converted to the right levels ... ?

Quoting page 7/8 of the datasheet, describing mode 0:

"This mode is selected when the MODE pin is low. In
this mode, data transfer is initiated by the device.
The MT88E43B receives the FSK signal,
demodulates it, and outputs the data directly to the
DATA pin (refer to Figure 14). For each received stop
and start bit sequence, the MT88E43B outputs a
fixed frequency clock string of 8 pulses at the DCLK
pin. Each clock rising edge occurs in the centre of
each DATA bit cell. DCLK is not generated for the
stop and start bits. Consequently, DCLK will clock
only valid data into a peripheral device such as a
serial to parallel shift register or a micro-controller.
The MT88E43B also outputs an end of word pulse
(data ready) on the DR pin. The data ready signal
indicates the reception of every 10-bit word
(including start and stop bits) sent from the network
to the TE/CPE. This DR signal can be used to
interrupt a micro-controller. DR can also cause a
serial to parallel converter to parallel load its data
into a microcontroller. The mode 0 data pin can also
be connected to a personal computer's serial
communication port after converting from CMOS to
RS-232 voltage levels."

The way I read it is that the clock pin must be connected to the mP but
the data pin can be connected to a PC ... ?




Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.