[Date Prev][Date
Next][Thread Prev][Thread Next][Date
Index][Thread Index]
Re: AW10U wiring help, please!
- To: ukha_d@xxxxxxx
- Subject: Re: AW10U wiring help, please!
- From: "mark_harrison_uk2" <mph@xxxxxxx>
- Date: Thu, 19 Jun 2003 07:51:05 -0000
- Mailing-list: list ukha_d@xxxxxxx; contact
ukha_d-owner@xxxxxxx
- Reply-to: ukha_d@xxxxxxx
Here's what I remember doing:
AW10.Neutral:
- existingsupply.neutral
- existingload.neutral
AW10.Live:
- existingsupply.live
AW10.Load:
- existingload.live
Obviously, common all the earths as well.
I guess someone else will be along in a few minutes to tell me what
I've got wrong :-)
Mark
--- In ukha_d@xxxxxxx, "garygfx" <garygfx@d...> wrote:
> I'm trying to fit an AW10U appliance module to replace a wall
switch
> that controls kitchen unit display lights. The terminals for the
> AW10U are Live, Neutral and Load. However, the existing switch has
6
> terminals. Under "Supply" it has Live, Neutral and Earth.
> Under "Load" it also has Live, Neutral and Earth. All 6
terminals
are
> in use and some have 2 wires going in to each terminal. How does
this
> translate to wiring them in to the AW10U please?
>
> None of the lighting units appear to be using the Earth so I guess
> that's 2 wires out of the way! ;-) Any ideas please?
>
> Thanks.
>
> Gary.
> -----
> All X-10'ed up apart from the kitchen! I'm sure the wife will love
it
> when it's done! :-7
Home |