The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024

Latest message you have seen: RE: Terminating Cable WAS ... Re: Sky+ at node zero


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Re: CBus introductory course



Yes, but if your cbus installation does not qualify as SELV, then you can't
do stuff with it that is limited to SELV, such as installing an SELV light
switch in your bathroom.

Paul

----- Original Message -----
From: "Keith Doxey" <ukha@xxxxxxx>
To: <ukha_d@xxxxxxx>
Sent: Monday, June 16, 2003 6:18 PM
Subject: RE: [ukha_d] Re: CBus introductory course


> 36V DC would not be a problem as Telephone lines are nominally 50V but
can
> be as high as 70V or 80V for digital lines and Telex.
>
> Power Over Ethernet (POE) is also around 48V. That carried Data and
Power
in
> the same cable.
>
> Keith
>
> www.diyha.co.uk
> www.kat5.tv
>
>
> > -----Original Message-----
> > From: Paul Robinson [mailto:ukcueman@xxxxxxx]
> > Sent: 16 June 2003 16:38
> > To: ukha_d@xxxxxxx
> > Subject: Re: [ukha_d] Re: CBus introductory course
> >
> >
> > Hi Rob,
> >
> > Apart from the qusetion of whether it would work, it was also
> > suggested to
> > me that the regulations require physical separation between
> > cables that
> > carry power from those that don't, even if they only carry
> > DC. For those
> > that are not familiar with this, cbus cat5 carries 15-36V DC to
power
> > devices. So it's possible that laying cbus cat5 next to other
> > cat5 breaches
> > the regs.
> >
> > I don't have a copy of the regs themselves, but I do have a
> > copy of "The
> > electrician's guide to the 16th edition of the IEE wiring
> > regulations" by
> > John Whitfield. Unfortunately, it isn't explicit on this
> > matter. The closest
> > relevant info I can find is that to be considered an SELV
> > system, "there
> > must be physical separation from the conductors of other
> > systems...". So
> > it's possible that an incorrectly installed CBus system does
> > not meet the
> > requirements of an SELV system.
> >
> > I don't know what the consequences of that are, nor whether
> > the regs are
> > really able to cope with this.
> >
> > Paul




Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.