Title: [ukha_d] Re: SOM1 relay board switching sound.
Good call Marc. Status response will be in the first release. The command list looks like this at the moment (subject to changes during development).
 
 
B1R1On - Board one, relay one turn on
B1R1Off - Board one, relay one turn off
B1R2On - Board one, relay two turn on
B1R2Off - Board one, relay two turn off
etc. etc. up to eight
 
The unit would return
B1R1OnOK
B1R1OffOK
etc. etc. up to eight again
 
Status response
B1STATUS - send back the status of the relays on board 1.
 
The unit would return
B1R1On,B1R2Off,B1R3On,B1R4Off, etc. etc. These would be comma delimited.
 
It is likely the command strings will be case sensitive initially. I can make them so they don't care, anyone have any views either way?
 
Baud speed either 9600 or 19200.
 
Ian
 
 
 
 
 -----Original Message-----
From: Marc Mosthav [mailto:marc@xxxxxxx]
Sent: 24 August 2002 07:42
To: ukha_d@xxxxxxxSubject: Re: [ukha_d] Re: SOM1 relay board switching sound.

My two pennies worth: status response. It would be nice if you could query the state of the relays.
 
Marc
----- Original Message -----
From: Amar Nagi
Sent: Friday, August 23, 2002 9:15 PM
Subject: RE: [ukha_d] Re: SOM1 relay board switching sound.

Features :

 

Off r1

On R2

Turn R1 in 2Min for 1hour

Flash R1 (interval)

Group Relays together like 1,2,3 so they can be toggled.

Eg When issued with the command “turn On R3” and then “turn On R2 - R3 would turn off before R2 Came on

 

All this can be software controlled from the plugin.

All I would need is the simple on/off instructions to send to the serial port.

What you think ?

 

 

 

-----Original Message-----
From: ian.bird@xxxxxxx [mailto:ian.bird@xxxxxxx]
Sent: 23 August 2002 16:04
To: ukha_d@xxxxxxxSubject: RE: [ukha_d] Re: SOM1 relay board switching sound.

 

Sounds good to me. Can you start putting together a wish list of features. I will be using a PIC micro controller and a serial interface at up to 19200. I might even make the baud rate selectable. Think about things like the commands you want to send e.g. R1 on, R1 off etc. You might want an acknowledgement as well. Lots of fun.

 

I am trying to keep it simple initially so commands like R1 on for 1 hour then xyz will not be in the first release.

 

Thanks

Ian

Ciba Vision (UK) Ltd
Tel:+44(0)1489 775570
Fax:+44(0)1489 779570
E mail: ian.bird@xxxxxxx

-----Original Message-----
From: Amar Nagi [mailto:groups@xxxxxxx]
Sent:
23 August 2002 15:16
To: ukha_d@xxxxxxxSubject: RE: [ukha_d] Re: SOM1 relay board switching sound.

I would love to be a beta tester,

I have homeseer and volunteer to write a plugin if you like

-----Original Message-----
From: ian.bird@xxxxxxx [mailto:ian.bird@xxxxxxx]
Sent: Fri 23/08/2002
14:45
To: ukha_d@xxxxxxx
Cc:
Subject: RE: [ukha_d] Re: SOM1 relay board switching sound.

Hi Amar

 

I have ordered the PCB's so assuming no mistakes on my part boards will be available from about the 9th September. I am away on hols for a little before that ;-))

 

Details and pictures are on my site at www.mollyology.com then projects and relay board. At the moment it is aimed at HV and Comfort users but I will be putting together a small simple serial interface for it. This latter bit will make it very similar to the unit you have. You can be my beta tester if you like ;-))

 

The relay board is opto isolated as well so none of that nasty AC stuff going anywhere near your precious PC.

Ian

Ciba Vision (UK) Ltd
Tel:+44(0)1489 775570
Fax:+44(0)1489 779570
E mail: ian.bird@xxxxxxx

-----Original Message-----
From: Amar Nagi [mailto:groups@xxxxxxx]
Sent:
23 August 2002 14:33
To: ukha_d@xxxxxxxSubject: RE: [ukha_d] Re: SOM1 relay board switching sound.

ian can i have details of your board please

 

-----Original Message-----
From: ian.bird@xxxxxxx [mailto:ian.bird@xxxxxxx]
Sent: Fri 23/08/2002 13:31
To: ukha_d@xxxxxxx
Cc:
Subject: RE: [ukha_d] Re: SOM1 relay board switching sound.

When I was designing my relay board I initially used reed relays which had some problems with things like capacitive loads, AC etc. The relays on the SOM1 look very similar so you may be experiencing similar problems. Check the relays are actually switching off somehow with the speakers connected and showing the problems. Alternatively use one of my boards <grin> which are rated up to 120v AC and everything else you can think of.

Ian

Ciba Vision (UK) Ltd
Tel:+44(0)1489 775570
Fax:+44(0)1489 779570
E mail: ian.bird@xxxxxxx

-----Original Message-----
From: Amar Nagi [mailto:groups@xxxxxxx]
Sent: 23 August 2002 13:26
To: ukha_d@xxxxxxxSubject: RE: [ukha_d] Re: SOM1 relay board switching sound.

i switched both + and -

 

 

-----Original Message-----
From: PatrickLidstone [mailto:patrickl@xxxxxxx]
Sent: Fri 23/08/2002 13:18
To: ukha_d@xxxxxxx
Cc:
Subject: [ukha_d] Re: SOM1 relay board switching sound.

Loudspeakers use an AC signal, not DC. There is no concept of a
common ground, so you can't switch it that way.

Patrick


--- In ukha_d@y..., "Amar Nagi" <groups@a...> wrote:
> i think you need to switch the live

>
>       -----Original Message-----
>       From: justin@g... [mailto:justin@xxxxxxx...]
>       Sent: Fri 23/08/2002 13:06
>       To: ukha_d
>       Cc:
>       Subject: [ukha_d] SOM1 relay board switching sound.
>      
>      
>
>       I recently purchased a SOM1 relay board
>       (http://www.phaedrusltd.co.uk/system/index.html)
>       I am running 2 sets of speakers connected to a soundcard over
CAT5 and thought
>       I would try switching using the relay board (that's not why I
bought it though)
>      
>       The wiring uses 4 cores, orange = left, green = right, w/o &
w/g = ground*.
>       When I switch the ground it just goes a bit quieter? Any
ideas why this
>       happens? I thought it would just switch the sound off!
>      
>       Cheers,
>       Justin.
>      
>       * I think it probably isn't a great idea to use 2 cores for
ground & 1 each for
>       left/right, but don't know why! I was thinking about
shielding.
>      



http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx

List of UKHA Groups here - http://groups.yahoo.com/group/UKHA_Grouplists/


Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.



http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx
List of UKHA Groups here - http://groups.yahoo.com/group/UKHA_Grouplists/


Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.


http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx
List of UKHA Groups here - http://groups.yahoo.com/group/UKHA_Grouplists/


Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.

http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx
List of UKHA Groups here - http://groups.yahoo.com/group/UKHA_Grouplists/


Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.

Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.