RE: Re: AWM2 2-way wiring problem
- To: <ukha_d@xxxxxxx>
- Subject: RE: Re: AWM2 2-way wiring problem
- From: "Jon Whiten" <jon@xxxxxxx>
- Date: Thu, 1 Aug 2002 21:47:45 +0100
- Mailing-list: list ukha_d@xxxxxxx; contact
ukha_d-owner@xxxxxxx
- Reply-to: ukha_d@xxxxxxx
Ah! just a quick thought, has she connected the second switch to the
red/blue pair? If so it will only transmit an X10 signal on
base-code-plus-one and not switch the light at all.
Regards,
Jon
http://www.whiten.co.uk/
> -----Original Message-----
> From: garygfx [mailto:garygfx@xxxxxxx]
> Sent: 01 August 2002 19:38
> To: ukha_d@xxxxxxx
> Subject: [ukha_d] Re: AWM2 2-way wiring problem
>
>
> Thanks Jon. My electrician wired one up at the light switch and
> another at the ceiling light to see if it made any difference. She
> says I have a neutral at the light switch so it shouldn't make any
> difference. Both methods produced the same results, but even when
the
> 2nd switch didn't turn the light on it sent an X10 code! I thought
> that was really strange. Why would it send an X10 code but not
turn
> the light on/off?
>
> I'll show her your diagram and see what she makes of it. Yes -
she!
> The male electricians I asked to help didn't want to know or they
> were totally baffled by it! I'm not omplaoning! ;-)
>
> Gary
>
>
Yahoo! Groups
Sponsor |
ADVERTISEMENT
|
|
For more information: http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe: ukha_d-subscribe@xxxxxxx
Unsubscribe: ukha_d-unsubscribe@xxxxxxx
List owner: ukha_d-owner@xxxxxxx
Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
Home |
Main Index |
Thread Index
|
|