Re: Swish discrete contol
The diode across the relay coil is for protection against back EMF,
stops
the driver circuit being damaged when the relay turns off. This would
only
be used in a DC circuit otherwise the diode would present its self as a
near
short circuit for half of the AC cycle.
Alancc
----- Original Message -----
From: Robert Crawshaw <golcarbob@xxxxxxx>
To: <ukha_d@xxxxxxx>
Sent: Saturday, April 06, 2002 6:35 PM
Subject: Re: [ukha_d] Swish discrete contol
>
>
> > Hmm..
> >
> > The relay I was using has a coil rated at 230VAC :(
> >
> > That being said, now I think about it, the problem I had was not
when
the
> > coil was energised: this correctly closed the curtains.
> > The problem was when the thing was turned *off* at this point,
the relay
> > chattered like crazy, as if it didn't actually switch off
correctly.
>
>
> ermm is this problem easily sorted with a diode across the coil
/??
> i seem to remember seeing this done quite a few times, cannot
remember
what
> the circuit was for though though :(
>
> Robert
Crawshaw
http://www.golcarbob.com
>
> The internet has had no effect on my life wwwhatsoever.com
>
> I am Dyslexia of
Borg Your
ass will be laminated
>
>
Yahoo! Groups
Sponsor |
ADVERTISEMENT
|
|
|
For more information: http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe: ukha_d-subscribe@xxxxxxx
Unsubscribe: ukha_d-unsubscribe@xxxxxxx
List owner: ukha_d-owner@xxxxxxx
Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
Home |
Main Index |
Thread Index
|
|