|
The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024
|
Latest message you have seen: Awesome New PTZ CCTV Camera Just Installed... |
[Date Prev][Date
Next][Thread Prev][Thread Next][Date
Index][Thread Index]
Newbie assistance....
- To: <ukha_d@xxxxxxx>
- Subject: Newbie assistance....
- From: Jerome O'Donohoe <jerome@xxxxxxx>
- Date: Sat, 06 Apr 2002 16:36:38 +0100
- Delivered-to: ukha_archive@xxxxxxx
- Delivered-to: mailing list ukha_d@xxxxxxx
- Mailing-list: list ukha_d@xxxxxxx; contact
ukha_d-owner@xxxxxxx
- Reply-to: ukha_d@xxxxxxx
Hi All,
Until I get the mac bits working, I'm tiddling with a PC laptop &
activehome. I've got 5 AM12's, an LM12, a TM12 and the PC I/f. I have
an
SS13 wall switch and a KR22 keyring remote. I've defined the modules
and
put them in on/off macros in Activehome, but commands from the remotes
don't
seem to be recognised by the interface and macros not executed. Is
there
something obvious I'm missing? The remotes control the units individually
if
the modules are on A1-4, but now I have the modules on B1-7 and the
remotes
are hard-coded to A1-3 and A1-4 I believe. Does everything have to be
on
the same housecode?
Cheers,
Jerome
--
"Ready...Fire...Aim..."
Jerome O'Donohoe, Re-recording Mixer. London, UK.
Yahoo! Groups
Sponsor |
ADVERTISEMENT
|
|
|
For more information: http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe: ukha_d-subscribe@xxxxxxx
Unsubscribe: ukha_d-unsubscribe@xxxxxxx
List owner: ukha_d-owner@xxxxxxx
Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
Home |
Main Index |
Thread Index
|
|