Yeah ... LCD projectors are even more annoyingly noisy but the MT1 is
definitely one of the quieter units out there.
Basically you need to look at building a box around the projector with a
glass front so that the image can project through. (Be carefull that you
angle the glass so that it's perpendicular to the projection angle or it
will bend the light coming through it - especially if you use "double
glazing" to really cut out the fan noise.) You may find that depending
on
the positioning of the projector that you can leave the front or back of
the
hush box open without getting too much of a noise penalty so if you can
leave the front open then that solves the potential problem of the glass
redirecting the light a bit. (This is more of a problem with CRT projectors
given the separate RGB guns.)
The box should be large enough that there's a few inches clear space around
the projector and a very good airflow through so possibly open vents at the
bottom rear of the hush box and an extraction point at the top front vented
to the outside world. I was looking at a dedicated flow in and out for mine
but I don't think I'll have the room in the ceiling void and it's a low
ceiling anyway so I'll probably have to do a "suck through"
design with the
source airflow being from the AV room itself.
The box should be lined with something dense enough to absorb or mask the
fan noise. Plasterboard and rockwool are usually pretty good either in
isolation or combination but you need to make sure that there's plenty of
ventilation for the projector or that baby will die. Sheetrock is great if
you're housing your projector in a coffee table build but be aware that
it's
bloody heavy and expensive (not only to buy but ship too as it's so heavy.)
Phil
> -----Original Message-----
> From: Kenneth Watt [mailto:kennethwatt@xxxxxxx]
> Sent: 24 June 2001 15:46
> To: ukha_d@xxxxxxx
> Subject: RE: [ukha_d] Home A/C Units - No Vent Kits - Help !
>
>
> Hush box, projector! More info please, I would love to dampen the
noise
> from the MT1.
>
> K.
>
> -----Original Message-----
> From: Phil Harris [mailto:phillip.harris1@xxxxxxx]
> Sent: 24 June 2001 15:38
> To: ukha_d@xxxxxxx
> Subject: RE: [ukha_d] Home A/C Units - No Vent Kits - Help !
>
>
> It's the hush box for the projector that's going to be the problem!
>
> Phil
>
> > -----Original Message-----
> > From: Phil Harris [mailto:phillip.harris1@xxxxxxx]
> > Sent: 24 June 2001 15:34
> > To: ukha_d@xxxxxxx
> > Subject: RE: [ukha_d] Home A/C Units - No Vent Kits - Help !
> >
> >
> >
> > Nah ... I intend to use a fairly hefty 8 inch centrifugal
ventilation
> fan
> > extracting through a large cavity which is fairly lightly wadded
with
> > Rockwool. The Rockwool will reduce the airflow which is why it
> > needs to be a
> > hefty ventilation fan but it will also reduce significantly the
sound
> > leakage ... also because the vent area will be about 9ft x 6in
(i.e.
> the
> > "step" up to a raised sort of stage area) then the air
velocity
> > will be low
> > anough not to be audiable.
> >
> > Phil
> >
> > > -----Original Message-----
> > > From: Mick Furlong [mailto:dorsai@xxxxxxx]
> > > Sent: 24 June 2001 15:29
> > > To: ukha_d@xxxxxxx
> > > Subject: RE: [ukha_d] Home A/C Units - No Vent Kits - Help !
> > >
> > >
> > > oh go on phil tell us the plan ;)
> > >
> > > a set of self opening velux windows mebbe ...I hear b&q
are doing
> > > a deal ;)
> > >
> > > Just trying to figure out how you can hide them?
> > >
> > > Only kidding
> > >
> > > Cheers
> > > Mick
> >
> >
> >
> >
> > ____________________________________
> > Automated Home UK
> > http://www.automatedhome.co.uk
> > ____________________________________
> >
> > Your use of Yahoo! Groups is subject to
> http://docs.yahoo.com/info/terms/
> >
> >
> >
>
>
>
>
> ____________________________________
> Automated Home UK
> http://www.automatedhome.co.uk
> ____________________________________
>
> Your use of Yahoo! Groups is subject to
> http://docs.yahoo.com/info/terms/
>
> _________________________________________________________ Do You
> Yahoo!? Get your free @yahoo.com address at http://mail.yahoo.com
>
>
> ____________________________________
> Automated Home UK
> http://www.automatedhome.co.uk
> ____________________________________
>
> Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
>
>
____________________________________
Automated Home UK
http://www.automatedhome.co.uk
____________________________________
Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
Home |
Main Index |
Thread Index
|