[Date Prev][Date
Next][Thread Prev][Thread Next][Date
Index][Thread Index]
Re: Opal XL PIR wiring
- To: <ukha_d@xxxxxxx>
- Subject: Re: Opal XL PIR wiring
- From: "Andrew Roberts" <andrew@xxxxxxx>
- Date: Tue, 19 Sep 2000 13:06:57 +0100
- Delivered-to: rich@xxxxxxx
- Delivered-to: mailing list ukha_d@xxxxxxx
- Mailing-list: list ukha_d@xxxxxxx; contact
ukha_d-owner@xxxxxxx
- References: <969363706.20698@xxxxxxx>
- Reply-to: ukha_d@xxxxxxx
-------------------------- eGroups Sponsor -------------------------~-~>
eLerts
It's Easy. It's Fun. Best of All, it's Free!
http://click.egroups.com/1/9068/9/_/2065/_/969365029/
---------------------------------------------------------------------_->
> 9. Opal XL PIR wiring
> From: "Campbell" <c.macd@xxxxxxx>
>
> Message: 9
> Date: Mon, 18 Sep 2000 20:35:21 +0100
> From: "Campbell" <c.macd@xxxxxxx>
> Subject: Opal XL PIR wiring
> Has anyone used one of these with Comfort, and if so can you advise
wiring.
> Thanks Campbell
> c.macd@xxxxxxx
Campbell,
This is covered in the Comfort Inst Manual under 'Negative Applied
Detectors'.
The detector output goes 'negative' on detection.
You dont need a relay. The lux output from the Opal is only useful if the
same PIR is triggerring the lighting response, due to the lux OP only being
active for 1 minute after each detection at night (strange but true).
Andrew
Comfort Home Controls (CHC)
Home |
Main Index |