The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024

Latest message you have seen: X10 dimming


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: House Wiring


  • To: ukha_d@xxxxxxx
  • Subject: Re: House Wiring
  • From: "Harrison, Mark (Alliance)" <Mark.Harrison@xxxxxxx>
  • Date: Tue, 16 Feb 1999 12:13:43 -0000
  • Delivered-to: listsaver-egroups-ukha_d@xxxxxxx
  • Mailing-list: contact ukha_d-owner@xxxxxxx
  • Reply-to: ukha_d@xxxxxxx

Steve,

Some points for you to consider:

1: I'm not convinced that STP is worth paying the premium for over UTP.
My own view is that you need a _really_ hostile EMF environment before
it makes much difference, and if you want to run very fast data, you're
probably better off with optical fibre anyway. (I may be about a year
out of date on this, though - what do others think?)

2: In my view, 2*UTP is a underspecified. I could, today, use up three
runs per room (1*phone, 1*balanced audio, 1*PC network). This is based
on well understood, off-the-shelf technology without going into any of
the fancy things that the gurus in this group do. Also remember that UTP
can be used as a generic multi-core system, so could subsequently carry,
say, thermostat, or PIR, or ...

3: Install trunking! Put in as much wide-gauge plastic trunking as you
can, together with the cabling equivalent of "rodding holes" at
junctions. Also, put several separate runs of string along each! This
will allow you to retro-fit the cabling of your choice in a few years
time by the simple expedient of tieing one end to the piece of string,
and pulling it through!

Regards,

Mark Harrison
European IT Manager, BP/Bovis Alliance
Tel: +44 181 869 1439
Fax: +44 181 423 7711
SMTP: Mark.Harrison@xxxxxxx



-----Original Message-----
From: steve@xxxxxxx
[mailto:steve@xxxxxxx]
Sent: 16 February 1999 11:40
To: ukha_d@xxxxxxx
Subject: [ukha_d] House Wiring


Hi,

I'm currently taking the opportunity to add some additional 'house
connectivity' whilst I'm rewiring my mains supply.

In each room I've installed a minimum of 2 * CAT5 STP, 4 * individually
screened audio cable, 2 * CT100 coax feeds. In there anything else I
should consider whilst the floors are still up?

Steve.

------------------------------------------------------------------------
What's everyone looking at? Check out the Top40 most requested stocks!
Plus quotes, charts, news, portfolios, mutual funds, and discussion.
All free, fast, and easy.   Visit:    http://www.stockmaster.com/?a=f5

eGroup home: http://www.eGroups.com/list/ukha_d
Free Web-based e-mail groups by eGroups.com


------------------------------------------------------------------------
Why are most stock sites so slow and annoying to use?  StockMaster.com
is fast, easy, powerful, and free!   Use company names, not ticker
symbols.  Track your portfolio.  Visit:   http://stockmaster.com/?a=f6

eGroup home: http://www.eGroups.com/list/ukha_d
Free Web-based e-mail groups by eGroups.com



Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.