I stand corrected Mark - but I think the rest of my comments apply
unfortunately :(

Do you have a link to info on ACE at all?

Ta,

Tony

> -----Original Message-----
> From: Mark Harrison [mailto:<a
href="/group/kat5-users/post?postID=d7FwspqD4vO_m928ox-V6URdBiLjNDPQb1jWmLjR3FFw8oRlrz1zqo-89_Do7kpqwHeisn0vq8_JFT1V9m7Y2NSTeg">Mark.Harrison@e...</a>]
> Sent: 19 February 2002 11:40
> To: <a
href="/group/kat5-users/post?postID=CFdXb8zUu1wWc8u41Sbt6KILApIygnI2Zn_J_jhPM-VI-zp0HcsRStxj-wu6rqtfTa13UhPC5VZ_Mnh2xoZWVNs">kat5-users@xxxxxxx</a>
> Subject: RE: [KAT5] Re: Knekt KAT5?
>
>
> > That's the Comfort PC software right?
>
> Wrong! It's software remote control of devices that was
> ORIGINALLY developed for interfacing with Comfort, but has
> come a long way since.
>
> Mark Harrison
> Head of Systems, eKingfisher
>
> -----Original Message-----
> From: Tony Butler [mailto:<a
href="/group/kat5-users/post?postID=zI-DT2lFv-COHlK4CoXbw8mCSr1SefF_wzET84tIdccvAyvARXfxBYQ6QqHJxPLmpKluTk5r2aXsi2iJ3oIUAg">tony@a...</a>]
> Sent: 19 February 2002 11:35
> To: <a
href="/group/kat5-users/post?postID=CFdXb8zUu1wWc8u41Sbt6KILApIygnI2Zn_J_jhPM-VI-zp0HcsRStxj-wu6rqtfTa13UhPC5VZ_Mnh2xoZWVNs">kat5-users@xxxxxxx</a>
> Subject: RE: [KAT5] Re: Knekt KAT5?
>
>
> Mike,
>
> That's the Comfort PC software right?
> I don't have comfort so no go.
> Even if I had, Linn don't publish the spec of the signalling
> interface they use so I have no idea how an RCU, which
> connects to a Line Receiver, tells the Intersekt that it
> wants to listen to source X. If you're talking about just
> 'tapping in' to the audio output from the intersekt, no go
> either as I would not be able to tell which source was being
> presented to the output I am 'listening' to, and thus would
> not know which source to tell the KAT5 switch to switch to :(
>
> cheers,
>
>
> Tony
>
>
> -----Original Message-----
> From: Mike Griffiths [mailto:<a
href="/group/kat5-users/post?postID=3voUsMxHfWcmB3F5EjyR1tQu32QKqsKWCv0Zmrzp6oSwxs4-84O_F6adC7oqyEE_O2zncb7BcOg0">mike@a...</a>]
> Sent: 18 February 2002 20:41
> To: <a
href="/group/kat5-users/post?postID=CFdXb8zUu1wWc8u41Sbt6KILApIygnI2Zn_J_jhPM-VI-zp0HcsRStxj-wu6rqtfTa13UhPC5VZ_Mnh2xoZWVNs">kat5-users@xxxxxxx</a>
> Subject: RE: [KAT5] Re: Knekt KAT5?
>
>
>
> Tony
>
> I'm sure this can be achieved by using ACE
>
> I control my linn preamp with it
>
> I'm sure you will be able to control the Kat5 switch with ACE
>
> And ace should be able to listen to your Linn setup
>
>
>
> Mike
>
> At Home
>
>
>
> -----Original Message-----
> From: Tony Butler [mailto:<a
href="/group/kat5-users/post?postID=zI-DT2lFv-COHlK4CoXbw8mCSr1SefF_wzET84tIdccvAyvARXfxBYQ6QqHJxPLmpKluTk5r2aXsi2iJ3oIUAg">tony@a...</a>]
> Sent: 15 February 2002 14:38
> To: <a
href="/group/kat5-users/post?postID=CFdXb8zUu1wWc8u41Sbt6KILApIygnI2Zn_J_jhPM-VI-zp0HcsRStxj-wu6rqtfTa13UhPC5VZ_Mnh2xoZWVNs">kat5-users@xxxxxxx</a>
> Subject: RE: [KAT5] Re: Knekt KAT5?
>
>
>
> Errr....mmmm... I'm not quite sure. Look (view as fixed font plz):
>
> -------VIDEO-----------------
> / \
> DVD --------AUDIO------ I ----ZONE1---- S ---ZONE1----
> Kitchen VIDEO ------AUDIO------ N ----ZONE2---- W ---ZONE2---- Lounge
> Tuner ------AUDIO------ T " 3 I " 3 Bedroom
> Radio ------AUDIO------ E " 4 T " 4 etc
> Jukebox ----AUDIO------ R " 5 C " 5
> SKY --------AUDIO------ S -----etc----- H etc
> etc E
> K
> T
>
>
> Ie, the video output of the DVD is connected to the
> Bugger. Nope that won't work.
> The audio from the DVD can be routed anywhere because say I
> select intersekt zone 2, switch automatically routes that to
> zone2 - lounge. But the video is plumbed into input 1 on the
> switch. Pants.
>
> There's probably a solution somewhere based on 2 switches,
> but I can't be arsed ATM. Wait until I get the switch eh? :)
> The question remains though: Do you think it will be
> possible to program the switch such that a scart trigger on
> input 1 can cause it to switch, say output 1, to display
> whatever is on input 1? Outside my dumb ideas, this could be
> useful to auto switch your TV to the CCTV input when someone
> is detected at the door - as long as the CCTV will generate
> the required SCART signals..
>
> I have several 'zones' already Linn'ed up, so I wanted to
> stick to a single means of switching sources rather than
> having something for A sources and something else for V
> sources. Of course if the RCU's would interface to your
> switch, then I just ditch the intersekt and away we go :-) Or
> if I could turn back time, I would save myself a fortune by
> not buying the Linn stuff &amp; just wait for your switch to
arrive :{
>
> Cheers,
>
> Tony
> > -----Original Message-----
> > From: Keith Doxey [mailto:<a
href="/group/kat5-users/post?postID=AZjfV7H-essaIi5e27WiMxYrSUUPmFTCagfh25IWz5Q3_ImsBccG24YELFm3mbpH-DZ_pb0SDKIPfJINjQ">kat5users@d...</a>]
> > Sent: 15 February 2002 13:38
> > To: <a
href="/group/kat5-users/post?postID=CFdXb8zUu1wWc8u41Sbt6KILApIygnI2Zn_J_jhPM-VI-zp0HcsRStxj-wu6rqtfTa13UhPC5VZ_Mnh2xoZWVNs">kat5-users@xxxxxxx</a>
> > Subject: RE: [KAT5] Re: Knekt KAT5?
> >
> >
> > Hi Tony,
> >
> > I *think* I get it now....
> >
> > You want to use the KAT5 switch so that you can have ANY of
> > your AV sources routed to <Room_Y> but in the event of
> > Intersekt Zone_X being active you want to select a DEFAULT
> > source for Room_Y taking the Audio from <Input_X> and Video
> > from wherever the DVD was connected.
> >
> > If you didnt want to select alternative Video sources then
> > you might as well use vanilla KAT5 without the switcher.
> >
> > I personally think you are over-complicating things as the
> > KAT5 switcher will be able to route everything by itself if
> > you can find a way of sending the commands to it. You could
> > then keep the Intersekt as a high end Audio system in the
> > main AV location.
> >
> > Keith
> >
> > -----Original Message-----
> > From: Tony Butler [mailto:<a
href="/group/kat5-users/post?postID=zI-DT2lFv-COHlK4CoXbw8mCSr1SefF_wzET84tIdccvAyvARXfxBYQ6QqHJxPLmpKluTk5r2aXsi2iJ3oIUAg">tony@a...</a>]
> > Sent: 15 February 2002 13:20
> > To: <a
href="/group/kat5-users/post?postID=CFdXb8zUu1wWc8u41Sbt6KILApIygnI2Zn_J_jhPM-VI-zp0HcsRStxj-wu6rqtfTa13UhPC5VZ_Mnh2xoZWVNs">kat5-users@xxxxxxx</a>
> > Subject: RE: [KAT5] Re: Knekt KAT5?
> >
> >
> > > Hi Tony,
> > >
> > > I'm confused :-(
> > >
> > > This is what I dont get....
> > > "could your switch be programmed such that having
received a SCART
> > > trigger on input X, it would always automatically output
that to
> > > output Y" ...if it ALWAYS routes X to Y then there is
no
> > point having
> > > a switch.
> > >
> > > The Intersekt only handles Audio, how will you select which
Video
> > > source you want, or are you saying "I select <AUDIO
1> on
> Intersekt
> > > for <Zone3> therefore I want the KAT5 Switch to select
> > <AVSource1> and
> > > Route it to <Zone3>".
> >
> > Yes, that's exactly what I'm thinking. ATM, I have intersekt
> > piping DVD audio around the house, Yamaha AC3 amp doing the
> > duty for the video signals &amp; AC-3 audio, and by
connecting
> > the DVD to the video, I can watch DVD in the bedroom on
> > crappy RF. I want to replace RF with KAT5.
> >
> > > If so, and assuming you built a reliable audio detection
> interface,
> > > how will you differentiate between Audio from <Audio1>
or
> <Audio3> ?
> >
> > I don't need to.
> > If I select DVD to play in the bedroom, then the intersekt
> > will output the DVD audio to the bedroom zone. If I then
> > decide to listen to the radio in the bedroom, it will output
> > the radio to the bedroom zone. Either way, the input on your
> > switch should be routed to what it knows as the bedroom zone.
> > Each output zone on the intersekt would be connected to a
> > different input on the KAT5 switch. It is the intersekt that
> > will differentiate between the various audio sources. The
> > switch just needs to know that input 1 always goes to output
> > 1, input 2 to output 2 etc....
> >
> > Or am I missing something here?
> >
> >
> > Cheers,
> >
> >
> > Tony
> >
> >
> >
> > To unsubscribe from this group, send an email to:
> > <a
href="/group/kat5-users/post?postID=OYhsoD_I5bbWYcOeuhO37O5Cz5pEQIj-v3J9067zuPm7-3aZk6xlkb0RQ24yXxOMgGhPw0DgDqFlaa40i0VbYEje4heHZ7FeDI0">kat5-users-unsubscribe@xxxxxxx</a>
> >
> >
> >
> > Your use of Yahoo! Groups is subject to
> > <a href="http://docs.yahoo.com/info/terms/";>http://docs.yahoo.com/info/terms/</a>
> <<a href="http://docs.yahoo.com/info/terms/";>http://docs.yahoo.com/info/terms/</a>>
> >
> >
> >
> > ------------------------
> > Yahoo! Groups Sponsor ---------------------~--> Sponsored by
> > VeriSign - The Value of Trust Do you need to encrypt all your
> > online transactions? Find the perfect solution in this FREE
> > Guide from VeriSign.
> > <a href="http://us.click.yahoo.com/vCuuSA/UdiDAA/yigFAA";>http://us.click.yahoo.com/vCuuSA/UdiDAA/yigFAA</a>
> <<a href="http://us.click.yahoo.com/vCuuSA/UdiDAA/yigFAA";>http://us.click.yahoo.com/vCuuSA/UdiDAA/yigFAA</a>>
> /26EolB/TM
> >
> >
> > --------------------------------------------------------------
> > -------~->
> >
> > To unsubscribe from this group, send an email to:
> > <a
href="/group/kat5-users/post?postID=OYhsoD_I5bbWYcOeuhO37O5Cz5pEQIj-v3J9067zuPm7-3aZk6xlkb0RQ24yXxOMgGhPw0DgDqFlaa40i0VbYEje4heHZ7FeDI0">kat5-users-unsubscribe@xxxxxxx</a>
> >
> >
> >
> > Your use of Yahoo! Groups is subject to
> > <a href="http://docs.yahoo.com/info/terms/";>http://docs.yahoo.com/info/terms/</a>
> <<a href="http://docs.yahoo.com/info/terms/";>http://docs.yahoo.com/info/terms/</a>>
>
> >
> >
>
>
>
>
>
> To unsubscribe from this group, send an email to:
> <a
href="/group/kat5-users/post?postID=OYhsoD_I5bbWYcOeuhO37O5Cz5pEQIj-v3J9067zuPm7-3aZk6xlkb0RQ24yXxOMgGhPw0DgDqFlaa40i0VbYEje4heHZ7FeDI0">kat5-users-unsubscribe@xxxxxxx</a>
>
>
>
> Your use of Yahoo! Groups is subject to the Yahoo!
> <<a href="http://docs.yahoo.com/info/terms/";>http://docs.yahoo.com/info/terms/</a>>
Terms of Service.
>
>
>
>
>
> To unsubscribe from this group, send an email to:
> <a
href="/group/kat5-users/post?postID=OYhsoD_I5bbWYcOeuhO37O5Cz5pEQIj-v3J9067zuPm7-3aZk6xlkb0RQ24yXxOMgGhPw0DgDqFlaa40i0VbYEje4heHZ7FeDI0">kat5-users-unsubscribe@xxxxxxx</a>
>
>
>
> Your use of Yahoo! Groups is subject to the Yahoo! Terms of
> Service <<a href="http://docs.yahoo.com/info/terms/";>http://docs.yahoo.com/info/terms/</a>>
.
>
>
>
> Yahoo!
> Groups Sponsor
>
> ADVERTISEMENT
>
<<a href="http://rd.yahoo.com/M=218512.1856015.3360178.1269402/D=egroupweb/S=1705";>http://rd.yahoo.com/M=218512.1856015.3360178.1269402/D=egroupweb/S=1705</a>
004726:HM/A=928901/R=0/*<a href="http://ad.doubleclick.net/clk;3788034;6800959;v%";>http://ad.doubleclick.net/clk;3788034;6800959;v%</a>
3<a href="fhttp://www.verisign.com/cgi-bin/go.cgi?a=b228473240057000";>fhttp://www.verisign.com/cgi-bin/go.cgi?a=b228473240057000</a>>

<<a href="http://us.adserver.yahoo.com/l?M=218512.1856015.3360178.1269402/D=egrou";>http://us.adserver.yahoo.com/l?M=218512.1856015.3360178.1269402/D=egrou</a>
pmail/S=1705004726:HM/A=928901/rand=874808922>

To unsubscribe from this group, send an email to:
<a
href="/group/kat5-users/post?postID=OYhsoD_I5bbWYcOeuhO37O5Cz5pEQIj-v3J9067zuPm7-3aZk6xlkb0RQ24yXxOMgGhPw0DgDqFlaa40i0VbYEje4heHZ7FeDI0">kat5-users-unsubscribe@xxxxxxx</a>



Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service
<<a href="http://docs.yahoo.com/info/terms/";>http://docs.yahoo.com/info/terms/</a>>
.

________________________________________________________________________
This email has been scanned for all viruses by the MessageLabs SkyScan
service. For more information on a proactive anti-virus service working
around the clock, around the globe, visit <a href="http://www.messagelabs.com";>http://www.messagelabs.com</a>
________________________________________________________________________



To unsubscribe from this group, send an email to:
<a
href="/group/kat5-users/post?postID=OYhsoD_I5bbWYcOeuhO37O5Cz5pEQIj-v3J9067zuPm7-3aZk6xlkb0RQ24yXxOMgGhPw0DgDqFlaa40i0VbYEje4heHZ7FeDI0">kat5-users-unsubscribe@xxxxxxx</a>



Your use of Yahoo! Groups is subject to
<a href="http://docs.yahoo.com/info/terms/";>http://docs.yahoo.com/info/terms/</a>







KAT5 Main Index | KAT5 Thread Index | KAT5 Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.