Re: Control occupancy sensor/motion sensor using Powerlinc V2 controller



arnie <parvezat6@xxxxxxxxxxxxxx> wrote:

>Hi
>I want to control occupancy sensor [PMS02] and motion sensor [MS14A]
>using powerlinc V2 controller USB [2414U]. There is also an RF
>transceiver present in the circuit. Manually i be able to control the
>x10 PRO modules using the motion sensor/transceiver combination. The
>lamp module is LM465.
>I want to control the motion sensor/occupancy sensor using PLC but no
>idea about how it can be done
>Can anyone suggest steps [if possible]
>Thanks
>Arnie

I do not understand what you mean by "control". All of the RF motion sensors
are one-way only. When they sense motion, they send an RF code to the
transceiver which then sends a PLC code on the powerline. There is no path
for sending messages to the motion sensors nor do the motion sensors have
any circuitry for receiving messages. The motion sensors are "programmed"
using their pushbuttons. All the Powerlinc controller can do is react to the
PLC codes on the powerline.