[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: Stanley Garge Door Status Indicator
Sorry - that you are using another macro capable unit that can send extended
codes wasn't clear from your other posts.
Here's the info I published on the 30001, 30003. I have no idea whether it
applies to your hardware. Your macro capable transmitter may have no way to
define the Type 29 (1D hex) codes which were only used by Stanley.
If you can find someone who will part with a BX24-AHT (it was a DIY project
I designed), it could send the Type 29 codes. I'll probably include them in
roZetta, as well, although there probably aren't many people using them.
Stanley Homelink Garage Door Status Indicator
=============================================
The Homelink Garage Door Status Transmitters send RF commands to the Vehicle
Interface which then sends Type 29 (hex 1D) extended code commands over the
powerline to the Garage Door Status Indicator. The unit code of the Status
Indicator changes with the number of sensors.
Here's an example log snippet:
17:57:56 RX: H5 Extended Data [10,1D]
17:57:57 RX: H5 Extended Data [10,1D]
17:58:01 RX: H5 Extended Data [11,1D]
17:58:02 RX: H5 Extended Data [11,1D]
The first hex byte indicates which sensor is sending and the open/closed
state of the door(s). Bits 0-2 indicate the open/closed states and bits 4-6
indicate the active door sensor. In the above example, 10 indicates the door
is closed and 11 indicates the door is open.
With one sensor, the unit code is 1 and the possible codes are:
Hex Binary Sender State
10,1D 0001 0000 1 CLOSED
11,1D 0001 0001 1 OPEN
With two sensors, the unit code is 5:
Hex Binary Sender States 2, 1
10,1D 0001 0000 1 CLOSED CLOSED
11,1D 0001 0001 1 CLOSED OPEN
12,1D 0001 0010 1 OPEN CLOSED
13,1D 0001 0011 1 OPEN OPEN
20,1D 0010 0000 2 CLOSED CLOSED
21,1D 0010 0001 2 CLOSED OPEN
22,1D 0010 0010 2 OPEN CLOSED
23,1D 0010 0011 2 OPEN OPEN
With three sensors, the unit code is 9:
Hex Binary Sender States 3, 2, 1
10,1D 0001 0000 1 CLOSED CLOSED CLOSED
11,1D 0001 0001 1 CLOSED CLOSED OPEN
12,1D 0001 0010 1 CLOSED OPEN CLOSED
13,1D 0001 0011 1 CLOSED OPEN OPEN
14,1D 0001 0100 1 OPEN CLOSED CLOSED
15,1D 0001 0101 1 OPEN CLOSED OPEN
16,1D 0001 0110 1 OPEN OPEN CLOSED
17,1D 0001 0111 1 OPEN OPEN OPEN
20,1D 0010 0000 2 CLOSED CLOSED CLOSED
21,1D 0010 0001 2 CLOSED CLOSED OPEN
22,1D 0010 0010 2 CLOSED OPEN CLOSED
23,1D 0010 0011 2 CLOSED OPEN OPEN
24,1D 0010 0100 2 OPEN CLOSED CLOSED
25,1D 0010 0101 2 OPEN CLOSED OPEN
26,1D 0010 0110 2 OPEN OPEN CLOSED
27,1D 0010 0111 2 OPEN OPEN OPEN
40,1D 0100 0000 3 CLOSED CLOSED CLOSED
41,1D 0100 0001 3 CLOSED CLOSED OPEN
42,1D 0100 0010 3 CLOSED OPEN CLOSED
43,1D 0100 0011 3 CLOSED OPEN OPEN
44,1D 0100 0100 3 OPEN CLOSED CLOSED
45,1D 0100 0101 3 OPEN CLOSED OPEN
46,1D 0100 0110 3 OPEN OPEN CLOSED
47,1D 0100 0111 3 OPEN OPEN OPEN
The Status Indicator requires that the sensors be "enrolled" by first
sending a signal to unit code 1 for the first sensor, then to unit code 5
for the second sensor, then to unit code 9 for the third sensor.
The RF signal from the sensor units appears to follow the same 32-bit format
used by other X-10 security RF transmitters with the exception that it
repeats immediately without the 40mS gap between copies used by most
transmitters.
Brian Allston <bka@xxxxxxxxxxxxxxxxx> wrote:
>
>I know that the Powerflash can only send standard messages. I am
>planning to use the X-10 Powerflash module transmission to trigger a
>macro in a SmartHome Powerlinc or other X-10 controller that is capable
>of sending extended codes.
http://www.davehouston.net
http://tech.groups.yahoo.com/group/roZetta/
roZetta-subscribe@xxxxxxxxxxxxxxx
comp.home.automation Main Index |
comp.home.automation Thread Index |
comp.home.automation Home |
Archives Home