[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Smarthome X10 module loosing their address
Sorry, but its still an empyric explanation.
Using more than 10 smarthome modules (2000STW and 2001STW) since months
without any trouble.
Discovered the strange behaviour already explained on the newsgroup
about loosing X10 address.
It happened after defining a SCENE address on an appliance module (2001
STW) with a 1132 controller.
Everyhting worked well for 20 hours until the module become
unreachable.
By using two ways functionaltiy, discovered that module Address was
becomed A ??? (meaning that the unit was no more correctly sent).
Tried the reinitialisation procedure without success (adress one more
time lost after less than one day).
The module is now recovered since 3 days by doing the following.
Reinit procedure
Assign address through micro switch, maxi controller on the same line.
Assign same scene address than base address also with maxi controller.
Seems that something should be buggy in chips logic or quality of the
signal during definition of primary and scene address is a key point.
Hope it helps
Thierry