[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Radionics handler update system recreated



On Wednesday, March 23, 2022 at 3:08:32 PM UTC-6, Jaime Watson1 wrote:
> On Monday, March 21, 2022 at 1:38:47 AM UTC-4, herber...@xxxxxxxxx wrote:=
=20
> > On Sunday, March 20, 2022 at 9:59:34 PM UTC-7, mleuck wrote:=20
> > > On Sunday, March 20, 2022 at 2:01:57 PM UTC-5, herber...@xxxxxxxxx wr=
ote:=20
> > > > On Sunday, March 20, 2022 at 7:40:47 AM UTC-7, mleuck wrote:=20
> > > > > On Monday, March 14, 2022 at 7:12:38 PM UTC-5, herber...@xxxxxxxx=
m wrote:=20
> > > > > > Hello all,=20
> > > > > >=20
> > > > > > Not sure how many this would be useful to, but I have remade th=
e "Radionics handler update system" that was shut down a few years ago. Thi=
s is the server used to download handlers to the Radionics d5200 programmer=
 from the phone line. If you end up needing a handler for the programmer wh=
en working on a super old panel, this might just be what you're looking for=
.=20
> > > > > >=20
> > > > > > This works just like the original system, just enter the phone =
number, handler name, and choose either "TELCO -> A" or "TELCO -> B" on the=
 programmer. Where the programmer asks you whether or not to include help f=
iles, choose "NO", the help files were never implemented to my knowledge an=
d haven't been included with any handler I have ever used.=20
> > > > > >=20
> > > > > > I do not have all the handlers archived to files as of now, sin=
ce it takes literal hours to transfer then verify them, but they will all b=
e available on my server soon. The telephone number for the server is +1(30=
4)451-7092, do keep in mind I haven't been able to test this anywhere offsi=
te, so if it doesn't work, just shoot me a message here and I'll look into =
it. It wouldn't surprise me if this suffers from the terrible quality of Vo=
IP lines nowadays.=20
> > > > > >=20
> > > > > > Additional information will be available here: http://www.proto=
starsolutions.cf/handler=20
> > > > > >=20
> > > > > > And an updated list of the handlers available on the server is =
available here:=20
> > > > > > http://www.protostarsolutions.cf/handler/handlers.txt=20
> > > > > >=20
> > > > > > Keith=20
> > > > > I have a set of Radionics and Honeywell handlers which I think ar=
e complete if you are interested, the read-me files appear to mention help =
files as well but I can't confirm it. Also has info on how to transfer them=
 etc=20
> > > > Mark,=20
> > > >=20
> > > > If they are contained within files i=E2=80=99d be happy to have the=
m, though I don=E2=80=99t know if I can post my email address here to send =
them to. If not, I think the only way to transfer them is with the blazing =
fast 300 baud modem integrated into the programmer.=20
> > > >=20
> > > > I=E2=80=99m not sure if it will remove it, but my email is herbertc=
lan4 [at] gmail [dot] com=20
> > > >=20
> > > > You can send them there and I=E2=80=99ll add them to the server whe=
n I get back.=20
> > > >=20
> > > > Keith=20
> > > According to a contained text file you can transfer them to a 5200 by=
 a standard PC by creating an RS232 cable although I've never tried it=20
> > Mark,=20
> >=20
> > This looks promising, I am away from home at the moment so I won=E2=80=
=99t be able to test it for a few days. It looks like someone was trying to=
 do what I did, but over the rs232 port and never finished it. It contains =
an executable that=E2=80=99s presumably used to save a handler to a compute=
r, but not transfer it back to another programmer. I=E2=80=99ll look into h=
ow they stored the data and see if I could directly convert it to the forma=
t I have handlers saved to my server with. It looks like they have most of =
the standard handlers already archived to files there.=20
> >=20
> > This should be useful, and will save a lot of time if it works how I th=
ink it does.=20
> >=20
> > Thanks,=20
> > Keith
> Hi All,=20
>=20
> This is really great that you are doing this. Im in desperate need of the=
 7212b handler (would save me lots of time and money) but the one that was =
in my 5200 was corrupted. Not sure if anybody has it.=20
>=20
> Thanks=20
> Kevin

Kevin,

The 7212B handler is now available on the server, let me know if you have a=
ny issues transferring it.

Remember to delete the corrupted handler first using the DELETE option, eve=
n if its not listed. Go to the UPDATE option in the menu, enter "7212B   " =
as the handler name, "NO" for include help, and "13044517092" for the phone=
 number. Select "Telco -> A", connect the programmer to a phone line, and h=
it enter. The programmer should dial out to the server and pull the new han=
dler.

It will take a while to transfer, but hopefully at the end you'll have the =
handler working again.

Keith


alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home